MT MPP 170
MT MPP260
MT MPP440
Ref. no.
9620000332
(MT 12170)
9620000200
(MT 12260)
9620000161
(MT 12440)
Recommended solar panel output (Wp)
40 – 170
50 – 260
50 – 440
Solar panel current
0 – 10.5 A
0 – 16 A
0 – 26.5 A
Solar panel voltage (Voc)
< 50 V
< 50 V
< 50 V
Max. standby current consumption
4 mA
4 mA
4 mA
House battery output
Charge/buffer/load current
0 – 12.5 A
0 – 18.5 A
0 – 32.0 A
Max. preliminary charging current
(charging voltage < 8 V)
6.3 A
9.3 A
16.0 A
Lead batteries
Nominal battery voltage
12 V
g
12 V
g
12 V
g
Recommended battery capacity
> 40 Ah
> 60 Ah
> 100 Ah
LiFePO4 batteries
Nominal battery voltage
12.8 –
13.2 V
g
12.8 –
13.2 V
g
12.8 –
13.2 V
g
Recommended battery capacity
> 30 Ah
> 45 Ah
> 90 Ah
Limitation of charging voltage
15.0 V
15.0 V
15.0 V
Unit fuse (Type FKS)
15 A
20 A
30 A
Auxiliary charging terminal for starting battery
Nominal voltage
12 V
12 V
12 V
Charging current
0 – 1.0 A
0 – 1.0 A