EN
CC32, CC40 AC/DC
Technical data
19
11
Technical data
I
Test/certificates:
The coolant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
CC32
CC40
Connection voltage:
12/24 V
g
120 V
w
, 60 Hz
Power consumption:
5.5 A (12 V
g
)/2.2 A (24 V
g
)
1.0 A (120 V
w
)
Cooling capacity:
+10 °C to –16 °C
(+50 °F to +4 °F)
Gross capacity:
32.5 l
40 l
Usable capacity:
31 l
38 l
Ambient temperature:
+16 °C to +32 °C
(+61 °F to 90 °F)
Noise emission:
49 dB(A)
Refrigerant quantity:
40 g
42 g
CO
2
equivalent:
0.057 t
0.060 t
Global warming potential (GWP):
1430
1430
Dimensions (L x W x H):
584 x 365 x 407 mm
(23“ x 14.4” x 16”)
584 x 365 x 446 mm
(23“ x 14.4” x 17.5")
Weight:
11.4 kg (25.1 lbs)
11.5 kg (25.4 lbs)
NOTE
If the ambient temperature is above +32 °C (+90 °F), the minimum tem-
perature cannot be attained.
CC40US-B-US.book Seite 19 Freitag, 20. Oktober 2017 10:13 10