EN
Operation
CFX100
16
•
Do not leave the cooling device open for longer than necessary.
•
If the cooler has a basket: For optimal energy consumption, position the basket
according to its position on delivery.
•
On a regular basis, make sure the lid seal still fits properly.
•
Defrost the cooling box once a layer of ice forms.
•
Avoid unnecessarily low temperatures.
7.3
Connecting the cooling box
!
Connecting to a battery
The cooling box can be operated with 12 V
g
or 24 V
g
.
A
For safety reasons the cooling box is equipped with an electronic system to prevent
polarity reversal. This protects the cooling box against short-circuiting when con-
necting to a battery.
Using supplied DC connection cable
A
1. Before starting up the device for the first time, check whether the operating
voltage and the battery voltage correspond (see type plate).
2. Plug the DC connection cable (fig.
2, page 3) into the DC voltage socket of
the cooling box (fig.
5, page 4).
3. Connect the red cable to the positive (+) battery terminal (fig.
WARNING! Fire hazard
•
When positioning the device, ensure the supply cord is not trapped
or damaged.
•
Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the device.
NOTICE! Damage hazard
Disconnect the cooling box and other consumer units from the battery
before you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
NOTICE! Damage hazard
For protection of the device the DC cable supplied is fitted with a fuse.
Do
not
remove the fuse.
Only use the DC cable supplied.
DometicCFX100Professional_OPM_4445103658_EMEA16_20xx-xx-xx.book Seite 16 Montag, 3. Januar 2022 4:13 16