Troubleshooting
25
10
Troubleshooting
Fault
Possible cause
Suggested remedy
Device does not
function, LED does
not glow.
Battery voltage is too
low.
Test the battery and charge it as needed.
The DC fuse is
defective.
Replace the DC fuse, see chapter
“Replacing the DC connection cable
fuse” on page 23.
The DC fuse inside the
device has blown.
This can only be repaired by an
authorised repair centre.
No voltage present in
the AC voltage outlet.
Try using another plug outlet.
The AC fuse is
defective.
Replace the AC fuse, see chapter
“Replacing the AC fuse” on page 23.
The integrated mains
adapter is defective.
This can only be repaired by an
authorised repair centre.
The device does not
cool (power is
connected, “POWER”
LED is lit).
Defective compressor.
This can only be repaired by an
authorised repair centre.
The device does not
cool (power is
connected, “POWER”
LED flashes orange,
display is switched
off).
Battery monitor is set
too high.
Select a lower battery monitor setting.
Battery voltage is too
low.
Test the battery and charge it as needed.
The display shows an
error message (e.g.
“Err1”) and the
appliance does not
cool.
The appliance has
switched off due to an
internal fault.
This can only be repaired by an
authorised repair centre.
The interior light of a
compartment flashes.
The lid of the
compartment has been
left open for more than
three minutes.
Close the lid of the compartment.
DometicCFX100Professional_OPM_4445103658_EMEA16_20xx-xx-xx.book Seite 25 Montag, 3. Januar 2022 4:13 16