EN
Technical data
CD 20, CD 30
18
12
Technical data
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
CD20
CD30
Connection voltage:
12 V
g
/24 V
g
Switch-off voltage:
10.4 V at 12 V
g
22.8 V at 24 V
g
Switch-on voltage:
11.7 V at 12 V
g
24.2 V at 24 V
g
Rated current:
12 V
g
: 3 A
24 V
g
: 1.5 A
Cooling capacity:
–2 °C to +12 °C (28.4 °F to 53.6 °F)
Capacity:
20 l
30 l
Climatic class:
N
Ambient temperature:
+16 °C to +32 °C (60.8 °F to 89.6 °F)
Relative humidity:
max. 90 %
Permanent inclination:
max. 30°
Refrigerant quantity:
38 g (1.3 oz)
42 g (1.5 oz)
CO
2
equivalent:
0.054 t (119.05 lbs)
0.060 t (132.28 lbs)
Global warming potential
(GWP):
1430
Dimensions:
fig.
1
, page 3
Weight:
16.1 kg (35.5 lbs)
18 kg (39.7 lbs)
Test/certificates:
CD20-30-IO-US.book Seite 18 Montag, 29. Mai 2017 4:41 16