EN
CRX1050, CRX1065, CRX1080
Installing and connecting the refrigerator
19
7.3
Changing the door hinge
You can also change the hinge of the door, so that it opens to the left rather
than the right.
➤
Proceed as shown in fig.
8
, page 6 to fig.
0
, page 7 to change the hinges.
7.4
Connecting the refrigerator
Connect the refrigerator to DC power
A
The refrigerator can be operated with a 12 V or a 24 V DC voltage supply.
For safety reasons, the refrigerator is equipped with an electronic system to
prevent the polarity being reversed. This protects the refrigerator against
reversed polarity when connecting to a battery and against short circuiting.
To protect the battery, the refrigerator switches off automatically if the voltage
is insufficient (see table below).
➤
Determine the required cross-section of the cable in relation to the cable
length according to fig.
a
, page 7.
Key for fig.
a
, page 7:
NOTICE!
To avoid voltage drops and loss of performance, keep the
connection cable as short as possible and avoid any additional
circuits.
Therefore avoid additional switches, plugs or power strips.
Disconnect the appliance and other electric consumers from
the battery before you connect the battery to a quick charging
device. Overvoltage can damage the electronics of the appli-
ance.
12 V
24 V
Cut-off voltage
10.4 V
22.8 V
Cut-in voltage
11.7 V
24.2 V
Coordinate axis
Meaning
Unit
l
Cable length
m
∅
Cable cross-section
mm²
Summary of Contents for CRX 1050
Page 2: ......
Page 3: ...CRX1050 CRX1065 CRX1080 3 CRX 1050 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 1065 2...
Page 4: ...CRX1050 CRX1065 CRX1080 4 1 2 3 5 4 6 7 CRX 1080 3 1 2 3 4 6 5 7 8 4...
Page 5: ...CRX1050 CRX1065 CRX1080 5 1 4 3 2 ca 50 mm 5 2 1 6...
Page 6: ...CRX1050 CRX1065 CRX1080 6 1 2 7 8...
Page 8: ...CRX1050 CRX1065 CRX1080 8 1 rt sw b 2 3 1 c 1 Vent Lock d...
Page 9: ...CRX1050 CRX1065 CRX1080 9 380 534 500 CRX 1050 e CRX 1065 448 525 545 f CRX 1080 475 640 528 g...
Page 121: ......
Page 122: ......
Page 123: ......