EN
CRX1050, CRX1065, CRX1080
Disposal
27
11
Disposal
!
➤
Place the packaging material in the appropriate recycling waste bins
wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
12
Troubleshooting
The meaning of the red LED (fig.
4
2, page 4)
When operational faults occur, it lights up several times. The number of times
it flashes depends on the type of fault.
Each flash lasts for one quarter of a second. A pause follows the sequence
of flashes. The sequence indicating the fault is repeated every four seconds.
WARNING! Children beware!
Before disposing of your old refrigerator:
Take off the doors.
Leave storage surfaces in the refrigerator so that children
cannot climb inside.
Number of
flashes
Fault
Possible cause
1
Supply voltage
The supply voltage is outside of the set
range.
2
Excessive fan current
The fan load on the electronics unit is
more than 1 A.
3
The motor does not start
The rotor is jammed.
The pressure difference in the cooling
system is too high (> 5 bar).
4
Speed too low
If the cooling system is overloaded, the
minimum speed of the motor of
1,850 rpm cannot be maintained.
5
Overheating of the electron-
ics unit
If the cooling system load is too heavy
or the temperature is too high, the
electronics can overheat.
Continuous
NTC fault
NTC is defective.
Summary of Contents for CRX 1050
Page 2: ......
Page 3: ...CRX1050 CRX1065 CRX1080 3 CRX 1050 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 1065 2...
Page 4: ...CRX1050 CRX1065 CRX1080 4 1 2 3 5 4 6 7 CRX 1080 3 1 2 3 4 6 5 7 8 4...
Page 5: ...CRX1050 CRX1065 CRX1080 5 1 4 3 2 ca 50 mm 5 2 1 6...
Page 6: ...CRX1050 CRX1065 CRX1080 6 1 2 7 8...
Page 8: ...CRX1050 CRX1065 CRX1080 8 1 rt sw b 2 3 1 c 1 Vent Lock d...
Page 9: ...CRX1050 CRX1065 CRX1080 9 380 534 500 CRX 1050 e CRX 1065 448 525 545 f CRX 1080 475 640 528 g...
Page 121: ......
Page 122: ......
Page 123: ......