Troubleshooting
29
Compressor is not running (connected to AC supply)
Poor cooling, increase in interior temperature
Unusual noises
Fault
Possible cause
Remedy
No voltage
Connection supply line interrupted
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is being applied,
but the compressor does
not operate
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to a
different position
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
Fault
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to a
different position
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor seldom
operational
Battery capacity exhausted
Charge the battery
Fault
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (touching the wall)
Bend the component
carefully away from the
obstruction
There is a foreign object stuck
between the cooling unit and the wall
Remove the foreign object
Fan noise
–
Summary of Contents for CRX 1050
Page 2: ......
Page 3: ...CRX1050 CRX1065 CRX1080 3 CRX 1050 1 2 3 5 4 6 7 1 1 2 3 5 4 6 7 CRX 1065 2...
Page 4: ...CRX1050 CRX1065 CRX1080 4 1 2 3 5 4 6 7 CRX 1080 3 1 2 3 4 6 5 7 8 4...
Page 5: ...CRX1050 CRX1065 CRX1080 5 1 4 3 2 ca 50 mm 5 2 1 6...
Page 6: ...CRX1050 CRX1065 CRX1080 6 1 2 7 8...
Page 8: ...CRX1050 CRX1065 CRX1080 8 1 rt sw b 2 3 1 c 1 Vent Lock d...
Page 9: ...CRX1050 CRX1065 CRX1080 9 380 534 500 CRX 1050 e CRX 1065 448 525 545 f CRX 1080 475 640 528 g...
Page 121: ......
Page 122: ......
Page 123: ......