EN
Operation
DE15F, DE24F, EA15F, EA24B, EA24D, EA24F
32
8.4
Switching the device on/off
➤
Press the on/off button for 6 seconds to switch the device on or off.
I
➤
Check the device for leaks after switching it on for the first time.
8.5
Locking/unlocking the control panel (DE15F, DE24F
only)
The control panel is equipped with a lock function to avoid unintentional settings.
➤
Press the on/off button and the light button simultaneously for 2 seconds to lock
or unlock the control panel.
8.6
Switching the light on/off
The interior LED turns on when the device is opened and turns off when it is closed.
➤
To switch on or off the interior LED while you keep the door open, press the light
button. The interior LED to switches on when you open the door next time.
EA15F, EA 24B, EA24D, EA24F only
➤
To switch on or off the interior LED permanently press the light button for
6 seconds.
✔
The manual light setting is activated.
✔
The display shows “CL” for a few seconds when the manual light setting is
switched on.
✔
The display shows “OP” for a few seconds when the manual light setting is
switched off.
8.7
Setting the temperature
➤
Press the setting button to adjust the temperature by 1 °C/1 °F.
✔
The temperature value on the display flashes during the temperature setting.
3 seconds after setting the temperature, the display shows the current tempera-
ture in the device. The temperature value changes by increasing or decreasing
until the set temperature in the device is reached.
NOTE
After switching on the device needs some time before the compressor
starts.
DometicD15F-24F_E15F-24B-24D-24F_IOM_4445103817_AMER3_202x-xx-xx.book Page 32 Wednesday, December 7, 2022 9:56 AM