EN
Technical data
DM 50NTE D, DM 50NTE F, DM 50NTE UPOE
24
12
Technical data
The refrigerant circuit contains R600a.
Follow EPA use conditions.
DM50NTE D
DM50NTE F
Voltage:
120 V
w
, 60 Hz (not DM50NTE UPOE);
48 V via Ethernet connection (only DM50NTE
UPOE)
Cooling capacity:
max. 21 °C (69.8 °F) below ambient temperature
(adjustable in three steps: 5 °C, 7 °C, 12 °C (41 °F,
44.6 °F, 53.6 °F))
Category:
2 (Cellar)
Total volume:
50 l
Climatic class:
N
Intended ambient temperature use:
+16 °C to +32 °C (+60.8 °F to +89.6 °F)
Refrigerant quantity:
28 g (0.06 lbs)
Dimensions main drawer W x D x H:
430 x 330 x 302 mm (16.93 x 12.99 x 11.89 in)
Dimensions mini drawer W x D x H:
159 x 285 x 88 mm (6.26 x 11.22 x 3.46 in)
Dimensions W x D x H (see also
fig.
550 x 524 x 418 mm
(21.65 x 20.63 x
16.46 in)
550 x 496 x 418 mm
(21.65 x 19.53 x
16.46 in)
Maximum internal storage load:
31 kg (68.3 lb.)
Weight:
23.5 kg (51.81 lbs)
23.0 kg (50.71 lbs)
Inspection/certification:
DometicDM50NTE-UPOE_IOM_4445103432_AMER4_202x-xx-xx.book Seite 24 Dienstag, 7. Dezember 2021 7:52 07