26
APPENDIX G: MAINTENANCE SCHEDULE
REFRIGERATOR OWNER MAINTENANCE YEARLY RECORD
Customer
Name:
Model
No.:
Date
of
Purchase:
Address:
Serial
No.:
City:
State:
Zip
Code:
Phone:
FIRST YEAR
Date:
Dealership:
Address:
City:
State:
Zip:
Phone:
Technician:
Cleaned Burner Assembly:
Yes / No
Cleaned/Check All Terminals Connections:
Yes / No
Cleaned/Inspect All Ground Connections:
Yes / No
Inspect and Test Door Seals:
Yes / No
Inspect and Tighten LP Lines:
Yes / No
Power Ventilator Installed:
Yes / No
Gas Safety Shutdown in 45 seconds:
Yes / No
ACTUAL
SPEC. RANGE
Electrode Gap
3/16"
Thermistor Reading
7-10,000 ohms @ 32°
D/C Voltage
9.5 to 15 volts D/C
A/C Voltage
120 Volts ± 10%
Thermocouple Reading
25-35 Millivolts
Delay Between Modes
Approx. 5 seconds
ICE MAKER MODELS
Inspect Water Valve and All Connections:
Yes / No
Inspect Heat Tape Switch for Proper
Operation:
Yes / No
SECOND YEAR
Date:
Dealership:
Address:
City:
State:
Zip:
Phone:
Technician:
Cleaned Burner Assembly:
Yes / No
Cleaned/Check All Terminals Connections:
Yes / No
Cleaned/Inspect All Ground Connections:
Yes / No
Inspect and Test Door Seals:
Yes / No
Inspect and Tighten LP Lines:
Yes / No
Power Ventilator Installed:
Yes / No
Gas Safety Shutdown in 45 seconds:
Yes / No
ACTUAL
SPEC. RANGE
Electrode Gap
3/16"
Thermistor Reading
7-10,000 ohms @ 32°
D/C Voltage
9.5 to 15 volts D/C
A/C Voltage
120 Volts ± 10%
Thermocouple Reading
25-35 Millivolts
Delay Between Modes
Approx. 5 seconds
ICE MAKER MODELS
Inspect Water Valve and All Connections:
Yes / No
Inspect Heat Tape Switch for Proper
Operation:
Yes / No