12
- Fasten screws starting with the screw next to boiler insulation, while
holding the unfastened end of hinge with your hand.
- Tighten screws. While fastening, check the leveling of hinge and plate.
Adjust as necessary.
2.2.4. Replacing lock
- Open
door.
-
Pull down rosette using 2 standard screwdrivers.
(Figure 31)
-
Pop up lock cover.
- With the bolt in locked position, pull the rim of lock cover onto the bolt
using a standard screwdriver to keep it from snapping back.
(Figure 32)
-
Snap off lock cover lid using 2 standard screwdrivers.
(Figure 33)
- Unscrew securing screws.
(Figure 34)
- Pull out lock.
(Figure 35)
- Reassembly is done in reverse order.
- Rosette and lock cover lid should be snapped in place applying slight
pressure.
When popping the lock cover lid open, the bolt must be in locked position.
Figure 31
Figure 32
Figure 33
Figure 35
Figure 34