7
CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower
side vent.
For “Certified Vent System Kits” see page 13.
For further information contact your dealer or distribu-
tor.
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9. It is es-
sential that all maximum or minimum dimensions are
strictly maintained as the performance of the refrigera-
tor is dependent on adequate flow of air over the rear of
the refrigerator.
NOTE: The upper vent should be centered over the
condenser coil at the back of the refrigerator.
VENTILATION HEIGHTS
CLEARANCES
Minimum clearances in inches to combustible materials
are:
G:
Top
0
K:
Side
0
L:
Bottom
0
M:
Rear
0
N:
See NOTE: Clearance “N” below.
NOTE: Clearance “M” is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance “N” is the distance between the bot-
tom of the lower vent to the roof material. For ventilation
height, see table VENTILATION HEIGHTS
See Figures 9, and 10.
Installation with roof
Minimum ventilation
vent and lower side vent
heights in:
Refrigerator
Inches
mm
NDE 1292
65
1651
LOWER VENT CUTOUT
13-5/8”
28-5/8”
FIG. 9
Ventilation
height
Condenser
K
G
K
N
L
M
NOTE: Wood Strip
MUST be in place
FIG. 10