B-21
EN
Figure B-20. Gateway defaults.
System
Check that the Number of
Engines and Number of
Gateways parameters match
the values entered into the
PCM. If they don’t, open the
PCM interface, make the
changes to the PCM
configuration, and cycle
power again. Do not try to
change the values in the
gateway interface because
they will be overwritten on
every power cycle.
LPS calibration
In this step you will you will run a calibration wizard that records the output
values from the lever position sensors (LPS) on the control head. In the course
of the calibration you will move both control levers to the following
prompted positions:
• Forward WOT (wide open throttle)
• Forward detent (engine at idle, forward gear engaged)
• Neutral
• Reverse detent (engine at idle, reverse gear engaged)
• Reverse WOT
You can abort the calibration wizard at any time by clicking
Abort LPS
Calibration
. All values will return to their defaults. The calibration will
automatically abort if an engine is started during calibration.
1.
Click
Start LPS Calibration
with the engines keyed on but
not
running.
Click
Yes
to acknowledge the Warning dialog. See figure B-21.
B.6.1
B.6.2
Summary of Contents for OPTIMUS 360
Page 10: ...1 4 EN This page left intentionally blank ...
Page 12: ...2 2 EN This page left intentionally blank ...
Page 22: ...4 4 EN This page left intentionally blank ...
Page 38: ...6 14 EN This page left intentionally blank ...
Page 70: ...9 8 EN This page left intentionally blank ...
Page 78: ...10 8 EN This page left intentionally blank ...
Page 80: ...11 2 EN ...
Page 82: ...12 2 EN This page left intentionally blank ...
Page 84: ...A 2 EN This page left intentionally blank ...
Page 86: ...A 2 EN This page left intentionally blank ...
Page 88: ...A 4 EN This page left intentionally blank ...
Page 115: ......