EN
Origo
Using the stove
19
8
Using the stove
8.1
Filling-in denatured alcohol
!
I
➤
Ensure all burners are turned off: turn the knob to “0”.
Otherwise the stove top cannot be opened.
➤
Ensure the stove is cooled down to room temperature.
➤
Pull the lower edge of the stovetop slightly forward while simultaneously press-
ing the catch (fig.
7
, page 6).
➤
Lift the stovetop.
➤
Check canister opening ensuring there’s neither fire nor glow.
➤
Take out the canister.
➤
Hold the canister tilted down (fig.
8
, page 6).
➤
Fill the denatured alcohol through the wire mesh into the opening of the canis-
ters.
The maximum capacity per canister must not exceed 1.2 l.
➤
Check the fuel level by tilting the canister vertically (fig.
9
, page 6).
Keep it in this position for 20 s, to make sure it's not overfilled. In addition, in the
case of accidental overfilling you can get rid of the surplus fuel.
✓
The maximum fuel level is reached when the fuel is visible at the bottom of the
opening.
I
WARNING! Danger of injury!
Never pour fuel through the burner openings in top of the stove (fig.
1
,
page 3).
Overfilling, spilt alcohol and hot objects can cause severe burns.
NOTE
If the stove is mounted with gimbals located in down position, the stove-
top must be raised to full upright position in order to remove the fuel
tanks for filling.
NOTE
The stove will operate even if the canister isn’t filled with the maximum
capacity.
Origo_1500_3000_6000.book Seite 19 Donnerstag, 22. Dezember 2016 12:36 12