28

If the fuse requires replacing at any time, the fuse cover/carrier should be

removed using a small screwdriver to lever it out. The old fuse should be

replaced  by  a  3  amp  ASTA  approved  BS  1362  fuse  and  the  fuse

cover/carrier must be refitted before the plug is used again.
If  the  fuse  cover/carrier  is  lost,  a  replacement  can  be  obtained  from  the

service shops. The fuse cover/carrier must be of the same colour as that of

the coloured insert in the base of the plug. In no circumstances must the

plug be used without a correct fuse cover/carrier fitted.
If the plug supplied on the mains lead is not suitable for the socket in your

home, it should be cut off and disposed of safely, or destroyed, to avoid any

possible shock hazard resulting from the plug being inserted into a 13 amp

socket elsewhere in the house. A suitable replacement plug should then be

fitted as given below.
General guide to fitting any plug
Ensure  the  lengths  of  wire  inside  the  plug  are  prepared  correctly.

Connections should be firmly made after all conductor strands are entered

into  the  terminal  posts.  When  preparing  the  cable    ends  take  care  not  to

damage the outer sheath, or the insulation surrounding the inner conductors.

Tighten all screws. Replace the top cover of the plug and secure.
Other versions
Your refrigerator has a 3-wire mains lead which is intended for connection

to a 3-pin plug and a properly earthed socket outlet.
IMPORTANT:

The wires in the mains lead of this appliance are coloured

in accordance with the following code:
GREEN-AND-YELLOW: EARTH      BLUE: NEUTRAL       BROWN: LIVE
As the colours of the wires in the mains lead may not correspond with the

coloured markings identifiying the terminals in your plug, proceed as follows:

the  wire  which  is  coloured  GREEN-

AND-YELLOW  must  be  connected  to  the

terminal  in  the  plug  which  is  marked  with  the

letter E or by the earth symbol

or coloured

green  or  green-and-yellow.  The  wire  which  is

coloured  BLUE  must  be  connected  to  the

terminal  which  is  marked  with  the  letter  N  or

coloured  black.  The  wire  which  is  coloured

BROWN  must  be  connected  to  the  terminal

which  is  marked  with  the  letter  L  or  coloured

red.

GB

Summary of Contents for RC1600

Page 1: ...207 5013 04 Type JCB 1 Gebrauchsanweisung Mode d emploi Instruzioni per l uso Operating instructions Gebruiksaanwijzing Instrucciones de manejo DE AT CH LU BE CH IT CH GB NL ES IE LU 0402...

Page 2: ...ate ventilation as a failure to do this will result in component failure and possible food loss refer to relevant instructions for unit installation under point 4 Before defrosting cleaning or mainten...

Page 3: ...ed This will result in a good energy saving cooling system 5 Cleaning Prior to initial use and later after defrosting or prior to a prolonged period out of operation clean the container and lid with l...

Page 4: ...correctly Connections should be firmly made after all conductor strands are entered into the terminal posts When preparing the cable ends take care not to damage the outer sheath or the insulation sur...

Page 5: ...kwise to position 0 a slight resistance will be felt just before this position Pull out mains plug 7 D C operation Do not use any additional form of energy mains gas A safety fuse must be installed in...

Page 6: ...to reduce the pressure in the gas cylinder to the operating pressure specified on the rating plate no other pressure may be used Needle valve operated gas control taps are NOT suitable for use with t...

Page 7: ...e burner every time after connection turn on the gas at the bottle and check the gas connections for leaks by applying a soap and water solution over them and watching for bubbles which would indicate...

Page 8: ...sition 13 Food and drink storage Foodstuffs and drinks should always be sealed when stored in the cooling unit Thus changes in taste and smell are avoided Food and drink should be so placed in the coo...

Page 9: ...lace the gas filter remove the filter from the duct and replace it with a new one Any other maintenance and repair works especially those relating to the cooling aggregate and the gas burner system ma...

Page 10: ...in accordance with our guarantee conditions 18 Technical Data Gas operation butane propane Rated thermal loading 112 W 118 W Min thermal loading 89 W 86 W Connected load gas 8 1g h 8 4 g h Connection...

Page 11: ...51 Fig 1...

Page 12: ...52 Fig 3 Fig 2...

Page 13: ...53 Fig 5 Fig 4 joint guarnizione afdichting junta joints guarnizione afdichtingen junta...

Page 14: ...54...

Page 15: ...55...

Page 16: ...Printed by Xerox Hungary Ltd Rev 2003 12 17...

Reviews: