GENERAL INSTRUCTIONS
1. The remote uses 2 “AAA” batteries. It is recommended that a spare set of batteries
be available.
2. All communications between the remote and receiver are validated when you hear a
tone or beep.
3. The orange button turns the unit “ON” and “OFF”.
4. All changes require the hand held remote to be pointed at the receiver.
5. When settings are changed, you must hear the tone or beep to indicate the new
settings are updated.
6. One of the LED’s (GREEN, ORANGE or RED) will be illuminated on the receiver de-
pending on the mode selected.
7. The receiver’s Green LED will blink to alert the operator to the following:
One blink with one second interval, frost control active.
Two blinks with one second interval, DC voltage high (18VDC and over).
Three blinks with one second interval, DC voltage low (9.75 VDC or lower).
Blink ON for 1/2 second, OFF 1/2 second - See step 8 Delay Timer, Paragraph a.
8. Delay Timer (Present in all Modes)
a.
The short-cycle delay is activated every time the compressor turns “OFF”. The
timer will delay the compressor from restart until the 150 second time has
elapsed.
b.
Delay on start cycle is activated when ever the fan is tuned “ON”. A 15 second
delay is started before the compressor or heat is turned “ON”.
c.
Delay-on-off cycle is present when the compressor or heat is turned “OFF”.
The fan will continue to operate for 15 seconds.
9.
Low Battery
a.
The low battery symbol will appear in the display window.
b.
When the low battery condition exists, and the remote sends a signal to the
receiver, it may be possible for the control system to go to the default setting
(Cool Mode with 74° F set point). If this condition occurs replace the batteries.
COOLING OPERATION
1. Push the “MODE” button until the cool symbol is displayed.
2. Select fan speed by pushing the “FAN” button until the desired fan speed is dis-
played.
a. High Speed (continuous fan, compressor cycles with thermostat )
b. Low Speed (continuous fan, compressor cycles with thermostat)
c. Auto High Speed (fan & compressor cycle with the thermostat)
AUTO
d. Auto Low Speed (fan & compressor cycle with the thermostat)
AUTO
3. Set the desired temperature by pushing the “UP(+)” or “DOWN (-)” button.
4. The receiver will beep when each change is completed. The GREEN LED will
light.
OPTION FEATURE (electric heat strip - if equipped)
1. Push the “MODE” button until the heat symbol is displayed.
2. Set the desired temperature by pushing the “UP(+)” or “DOWN (-)” button.
3. The receiver will beep when each change is completed. The GREEN LED will
light.
FAN ONLY OPERATION
1. Push the “MODE” button until the fan symbol is displayed.
2. Select fan speed by pushing the “FAN” button until the desired fan speed is dis-
played.
a. High Speed (continuous fan operation)
b. Low Speed (continuous fan operation)
3. The receiver will beep when each change is completed. The GREEN LED will
light.
ROOM TEMPERATURE DISPLAY
1. Press the “ROOM” button to display the temperature at the remote location.
2. The Room symbol will appear beside the temperature display.
SLEEP OPERATION
1. The cool, heat or furnace mode must be selected.
2. Set the temperature at the desired level, and push the sleep button. The sleep symbol
will appear on the display and a beep will sound indicating that the unit is in sleep
mode. See TIMER OPERATION.
Note: In the sleep mode the temperature will be offset by 2
o
F of the set point, which
means, if the set point is 77
o
F (during the cool operation) then in sleep mode it will
automatically change to 79
o
F. The sleep settings will become effective 2 hours after the
sleep mode is selected.
FURNACE OPERATION (if equipped)
1. Push the “MODE” button until the furnace symbol is displayed.
2. Set the desired temperature by pushing the “UP(+)” or “DOWN (-)”
button.
3. The receiver will beep when each change is completed. The RED LED will light.
DRY - AIR OPERATION
1. Push the “MODE” button until the dry - air symbol is displayed.
2. Set the desired temperature by pushing the “UP(+)” or “DOWN(-)” button.
3. The receiver will beep when each change is completed. The GREEN LED will
light. See TIMER OPERATION.
Note: In this mode the receiver monitors the room temperature in relationship with the set
point. If the temperature is 1 °F above the set point the compressor and low fan will cycle
“ON” for 15 minutes and “OFF” for 3 minutes. If the room temperature drops below the
set point the compressor and low fan will cycle “ON” for 6 minutes and “OFF” for 15
minutes until the set point is reached.
+
-
MODE
10:00
AUTO
75
°F
Mode
Fan
Orange
ON/OFF Button
Up (+)
Down (-)
Operation Mode
Display Window
Military Time
Temperature
Fan Mode
Display
REMOTE CONTROL
(w/door closed)
Room Temperature
Low Battery
AUTO CHANGE OPERATION
1. Push the “MODE” button until the auto change symbol is displayed.
2. Set the desired temperature by pushing the “UP(+)” or “DOWN (-)” button.
3. The receiver will beep when each change is completed. The GREEN LED will
light.
Note: In the auto change mode the temperature will be maintained in the vehicle without
the need to select cool or heat. A furnace or heat strip must be present and operational
before this feature can operate. If the installation contains both a heat strip and furnace
this feature will not select the furnace mode. Furnace mode must be selected manually.