background image

Trailer wall

I

s

Burner plate or

I

Working counter

Air

FLOOR LEVEL INSTALLATION

FIG. 1

vents

VENTILATION

The air vents, illustrated below, are contained in the following kits. These vents must be used and

must not be modified in any way.

USA: 

Dometic  Kit No. 1 (containing 1 upper

vent 123, and 1 lower vent 183).

CANADA: Dometic Kit VT24 (containing 1
upper vent VT24-II, and 1 lower vent VT24-I).

Upper vent

opening

17 1/2” x 7”

Upper Vent

 

,

 

INSTALLATION

ABOVE FLOOR LEVEL

FIG. 

2

Recess in

trailer to

house refrigerator

Height 22 1/2”

FIG. 

3

ITE:

When necessary, the

underside of the top
of the recess should
be  cut away locally
at the front to give
clearances for the

travel 

catch support

at one side and the
upper hinge arm at

*This is the minimum height allowable. Where possible, this height should be raised by up to

the other side.

11 inches in order to increase the natural air-flow to give best cooling unit performance.

3

Summary of Contents for RM211

Page 1: ...ALES CORP 7895 S W Hunziker Rd Portland OR 97223 503 620 9510 TWX 910 458 8838 DOMETIC SALES CORP 902 Avenue R Grand Prairie TX 75050 214 641 4277 TWX 910 866 4626 Canada EXECUTIVE OFFICE DOMETIC CANADA INC 2316 South Service Road West Oakville Ontario L6J 5A2 416 827 9811 TELEX 06 982234 SALES OFFICES DOMETIC CANADA INC 6019 3rd Street SE Calgary Alberta T2C 1 R4 403 279 2669 TELEX 038 21885 DOME...

Page 2: ...hes This is the minimum height which can be allowed over the condenser fins Wherever possible this height should be increased by up to 11 inches the more ventilation you provide the better the performance you can expect from the refrigerator The refrigerator should be installed in accordance with the illustra tions on page 3 Both the flue gases and the ventilation air must pass to the outside and ...

Page 3: ...nt VT24 II and 1 lower vent VT24 I Upper vent opening 17 1 2 x 7 A Upper Vent INSTALLATION ABOVE FLOOR LEVEL FIG 2 Recess in trailer to house refrigerator Height 22 1 2 FIG 3 ITE When necessary the underside of the top of the recess should be cut away locally at the front to give clearances for the travel catch support at one side and the upper hinge arm at This is the minimum height allowable Whe...

Page 4: ...nto a circulating flow of hydrogen gas If the evaporator is not level the liquid may accumulate forming pockets which can impair the gas circulation or block it completely in which case cooling will stop When the trailer is stationary for a period it must be level so that the refrigerator can operate properly When the trailer is being parked therefore the level should be checked preferably by mean...

Page 5: ... any thing else Frost will form gradually on the cooling fins and in and on the frozen food compartment It is a mistake to assume that an accumulation of frost gives a colder cabinet for the most efficient and economical operation the refrigerator should be defrosted regularly about every ten to fourteen days depending on the particular conditions of use Remember to level the trailer when stopping...

Page 6: ...e heater in its metal pocket Bend back the retaining wire clip at the top of the pocket and lift the heater from the pocket at the same time withdrawing its leads from the armoured sleeve Check that the new heater is of the correct type then fit it in the metal boiler pocket at the same time threading the three leads through the armoured sleeve This operation will be assisted if the ends of the le...