9
EN
Diagnostic Procedures
Component
Diagnostic Question
Action Based On Status
Page
Cooling Unit
Does the refrigerator not get cold
enough in any operating mode?
Perform a diagnostic on the power supply.
Perform a diagnostic on the gas pressure if the
problem occurs during gas operation.
Perform a diagnostic on the ventilation fan(s),
if installed.
If the problem persists, replace the cooling
unit.
Is a loud gurgling noise coming from the
cooling unit?
Replace the cooling unit.
Is there a strong smell of ammonia?
Door
Does the refrigerator not get cold
enough in any operating mode?
Does frost build up rapidly?
Does condensation form around the
frame?
1. Inspect the door and door gasket for
any damage that would prevent it from
closing properly.
2. If damage is observed, replace the door.
1. Test the door gasket.
2. If the gasket is weak at any point, repair it.
3. After 24 hours, test the gasket again.
4. If the gasket remains weak, replace the
door.
Confirm with the owner that the door has not
been held open or opened often enough to
allow a substantial volume of warm air to enter.
N/A
Electrode
Does the refrigerator not operate in gas
mode?
1. Inspect the ceramic insulator for cracks or
breaks in the ceramic casing.
I
A hair line crack at the electrode can be
difficult to see.
2. If cracks or breaks are observed, replace
the electrode.
1. Confirm that the electrode is securely
held by its clip.
2. Confirm that the tip of the electrode is
positioned 3/16 in. (4.8 mm) from the
slots in the burner.
3. If the electrode is out of position, adjust it.
1. Turn on the refrigerator in gas mode and
confirm that the electrode generates a
spark.
2. If the electrode fails to generate a spark,
replace it.