background image

CLEARANCES

Minimum clearances in inches to combustible materials are

G. Top 0

K. Side 0
L: Bottom 0
MRear 1
N: See example below

Clearance M between the rearmost part of the refrigerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the minimum

ventilation height

See Fig 11 and examples below

Fig.1 1

Refrigerator Overall product Installation product Recess

Distance between

model dimensions dimensions dimensions top of condenser

and top of

Height Width Depth Height

Width Depth Height Width Depth refrigerator

A B

C h 

d H

W D e

inch 

30 3/8         21 11/16      22 1/16

      20 1/4          20 3/8         29 3/4        20 1/2          21 3/8          1 1/4

RM2400 inch  

32 15/16     23                24 11/16    32 1/8          21 9/16       22 15/16     32 5/16        21 13/16      23 15/16      1 1/4

RM2500 inch  

40 13/16     23                24 11/16    40 21 9/16       22 15/16     40 3/16        21 13/16      23 15/16      1 1/4

RM2600 inch  

52              23                 24 11/16    51 3/16        21 9/16       22 15/16     51 3/8          21 13/16      23 15/16     1 1/8

RM2800 inch  

57 15/16    24 15/16       24 11/16    57  1/8         23 7/16       22 15/16      57 1/2         23 13/16     23 15/16     1 1/8

This method of installation and these clearences  will give you adequate space for servicing and proper installation.

d

e

h

EXAMPLES

The clearance N for the RM 2300 model is derived at in the
following way.

Installation with upper and lower side vents
N= Minimum ventilation height 37 minus installation height

29 9/16 plus distance between condenser top and refringera-
tor top 1 114

in: N=37-29  9/16+1  1/4=8 11/16 inches
mm: N=940-751+32=221  mm

Installation with roof vent and lower side vent

N=Minimum ventilation height 31 minus installation height
29 9116 plus distance between condenser top and refrigera-
tor top 1 114 plus distance between roof surface and roof vent
cap 5 114

in: N=31 -29 9/16+1 1/4+5 1/4=7 15/16 inches
mm: N=787-751+32+134=202  mm

Fig.1 2

View from above

Summary of Contents for RM2300

Page 1: ...all your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vi cinity of this or any other appliance Page Installation 5 8 Instructions for use 9 10 Gas equipment 10 Electric equipment 10 11 Maintenance 11 Fault tracing 11 Door panel 12 mD emetic 1 I quality leisure line products SERVICE OFFICE DOMETIC SALES CORP 509 South Poplar LaGrange IN 4676...

Page 2: ...valve 3 Thermo couple element 4 Coupling 7 Thermostat 9 Cut off valve 10 Nipple 11 Nut 14 Switch 23 Lighter 26 Burner 27 Electrode 29 Terminal 30 Sealing ring 31 Snap catch 33 Burner housing 35 Burner retainer 36 Terminal 12 120V 38 Burner jet 42 Plug 43 Cover 46 Cover 47 Flue baffle 50 Heater 52 Bushing 53 Retaining ring 30 ...

Page 3: ...urner jet Thermo couple element 43 Cover Coupling 46 Cover Thermostat 47 Flue baffle Cut off valve 50 Heater Nipple 51 Bushing Nut 52 Switch Clamping plate 53 Flue top Reigniter 55 Label for 12V Burner 57 Burner retainer Electrode 59 Push rod Terminal block 60 Shaft thermostat Sealing ring 61 Shaft switch Snap catch 62 Lead for 12 120V Burner housing 64 Flexible cord 3 ...

Page 4: ...ple element Coupling Thermostat Cut off valve Nipple Nut Switch Reigniter 24 Gas tube 29 Terminal block 31 Snap catch 32 Burner 33 Electrode 36 Terminal block 36 Burner jet 43 Cover 46 Nipple 47 Flue baffle 50 Heater 51 Nipple 54 Flue cap 55 Protection plate 59 Push rod 60 Shaft thermostat 61 Shaft switch 64 Flexible cord 67 Burner housing ...

Page 5: ...with a 3 8 SAE UNF 5 8 18 male flare connection All completed connections should be checked for leaks with soapy water The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11 inches water column When testing the gas supply system at test pressures in excess of 1 2 psig the refrigerator and its individual shutoff valve must be disconnected from ...

Page 6: ...t Loosen the screws fixing the refrigerator to the enclosure and remove the refrigerator When replacing the refrigerator make sure that the sealing strips are properly positioned After reassembly the gas connection should be checked for leaks TEST OF THE GAS SAFETY SHUTOFF The gas safety shutoff device must be tested after the refrigera tor is placed in operation Refrigerator wlth piezo ignitor Fi...

Page 7: ... METHODS OF INSTALLATION The methods of installation are shown in figures 10 a and 10 b It is essential that all maxlmum or minimum dimensions are strictly maintained as the performance of the refrigerator is dependent on an adequate flow of air over the rear of the refrigerator VENTILATION HEIGHTS Minimum ventilation heights in inches and mm RM2300 in 37 31 RM2400 in 3 4 RM2500 in 42 RM2600 in 5 ...

Page 8: ... 40 3 16 21 13 16 23 15 16 1 1 4 RM2600 0 inch 52 23 24 11 16 51 3 16 21 9 16 22 15 16 51 3 8 21 13 16 23 15 16 1 1 8 RM2800 0 inch 57 15 16 24 15 16 24 11 16 57 1 8 23 7 16 22 15 16 57 1 2 23 13 166 23 15 16 1 1 8 This method of installation and these clearences will give you adequate space for servicing and proper installation d e T h EXAMPLES The clearance N for the RM 2300 model is derived at ...

Page 9: ...essed When lamp E goes out wait 15 sec and release button C If the lamp comes on again repeat the procedure If flame blows out reignition will take place automatically To shut off the refrigerator turn the knob A to off position Electric Operation Fig 1 2 3 1 Check that the 120 Volt plug is correctly connected to the main supply When the refrigerator is equip ped for 12 Volt D C operation the low ...

Page 10: ...le The flue baffle is suspended from the top and must be in position 2 Disconnect the heater leads in the central tube of the cooling unit 3 Pull off the metal hose The Flame Failure Safety Device The tip of the thermo couple must reach in over two slots of the burner To replace the thermocouple pro ceed as follows 1 2 3 4 5 6 7 Remove the cover Unscrew plug and pull thermocouple straight out Remo...

Page 11: ......

Page 12: ...or frame 3 Rend the panel gently so that the free side of the panel can be slipped into the corresponding groove of the door frame 4 Push the panel downwards so that the lower horizontal edge of the panel is fitted into the bottom groove 5 Between the upper edge of the panel and the door frame there is now a gap which should be covered by the decora tion strip Put the strip across the door so that...

Reviews: