background image

REFRIGERATOR REMOvAL

Disconnect the 230- 240 V AC voltage and 12 V 

DC voltage leads.

Shut off the gas supply at the LP tank. 

Disconnect the gas supply line. Always use a 

back up wrench when loosening and tightening 

connections.
Cap the gas supply line, loosen the screws an-

choring the refrigerator to the enclosure and slide 

the refrigerator out of the compartment.
When replacing the refrigerator make sure that 

the sealing strips are properly positioned.
Replacement is the reverse of removal. Check all 

connections for gas leaks. 

1.

2.
3.

4.

5.

6.

To mount the door panel - snap in

Open the door 90 degrees.
Remove the door decoration  

strip (2) by gently pushing the 

 

four tabs away with a flat blade 

screwdriver (1).

Insert the vertical edges  

into the grooves of the door  

frame (3).

Push the panel downward  

so that the lower horizontal  

edge of the panel (4) is fitted 

 

into the bottom grove (5).
Snap in the decoration strip (2).

1.
2.

3.

4.

5.

1

2

2

3

3

4

5

INSTALLATION INSTRUCTIONS

Before leaving

Once the installation is complete, test the operation of the 

refrigerator and instruct the user on it’s correct operation. 

If the appliance fails to operate correctly, contact your local 

Dometic Service provider.

Summary of Contents for RM2453 and

Page 1: ...a ble vapors and liquids in the vicinity of this or any other appliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For...

Page 2: ...nomical operation the refrigerator must be installed and used as described in these instructions Follow the instructions in this manual The refrigerator is quality guaranteed However we are not respon...

Page 3: ...completely block it resulting in a loss of cooling Note Any time the vehicle is parked for several hours with the refrigerator operating the vehicle must be levelled to prevent this loss of cooling W...

Page 4: ...and used without modification An opening toward the outside at floor level in the refrigera tor compartment must be provided for ventilation of heavier than air fuel gases The lower vent of the recom...

Page 5: ...ip is ap plied to the rear surface of the front frame for this purpose The sealing should provide a complete isolation of the appliance s combustion system from the vehicle interior Note Be careful no...

Page 6: ...ed after the refrigerator is set into the cut out opening Install the lower front strip by slid ing it under the bottom hinge plate The hinge plate can be on the right or left side depending on the do...

Page 7: ...buttons C and D Apply a non corrosive commercial bubble solution to the burner jet Be careful not to damage the burner jet 1 2 3 4 5 6 Installation instructions No bubbles should appear at the openin...

Page 8: ...led on the tow vehicle or in the caravan The relay will automatically shut off the 12 V DC power to the refrigerator when the ignition is turned off CHANGING DOOR SWING The refrigerator is equipped wi...

Page 9: ...al Check all connections for gas leaks 1 2 3 4 5 6 To mount the door panel snap in Open the door 90 degrees Remove the door decoration strip 2 by gently pushing the four tabs away with a flat blade sc...

Page 10: ...ator on LP gas Turn off the gas bottle WARNING REGULATING THE TEMPERATURE The refrigerator is equipped with a thermostat that can be adjusted by turning the knob B to different setting to maintain the...

Page 11: ...igerator leaving the drip tray under the finned evaporator Leave the cabinet and freezer doors open Filling the ice tray with hot water and placing it on the freezer shelf can reduce defrosting time D...

Page 12: ...ably clean and free of soot Heavy soot formation indicates improper functioning of the burner The flue and burner both require cleaning in the following manner Unplug the refrigerator power cord from...

Page 13: ...240 volt power cord to the outlet and reconnect or turn on the 12 volt DC power Check LP gas safety shutoff 13 14 15 16 17 Maintenance service Electrode Burner tube 1 8 to 3 16 3 5 mm Troubleshooting...

Page 14: ...s DC 12 Volts DC Reigniter Heater Cover Terminal block Flexible cord Inlet fitting Manual gas shutoff valve 12 volt terminal block Evaporation Tray Burner jet Drain water hose Screw for protection cov...

Page 15: ...15 Appendix B wiring diagram...

Page 16: ......

Reviews: