background image

3

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

DIAGNOSTIC SERVICE MANUAL

Dometic

Dometic

Dometic

Dometic

Dometic

®  

®  

®  

®  

®  

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

RM3604/3804 AES

®

®

®

®

®

Refrigerators

Refrigerators

Refrigerators

Refrigerators

Refrigerators

SECTION 1

SECTION 1

SECTION 1

SECTION 1

SECTION 1

A

A

A

A

AC 

C V

V

V

V

VOL

OL

OL

OL

OLT

T

T

T

TA

A

A

A

AGE REQ

GE REQ

GE REQ

GE REQ

GE REQUIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

The refrigerator is a 120 volt AC, 60 Hz appliance. The
proper operating range is 100 to 132 volts. Check the AC
volts at the receptacle where the refrigerator is attached.
If voltage is outside of the proper operating range, correct
the power source problem.

SECTION 2

SECTION 2

SECTION 2

SECTION 2

SECTION 2

A

A

A

A

AC COMPONENTS —

C COMPONENTS —

C COMPONENTS —

C COMPONENTS —

C COMPONENTS —

HEA

HEA

HEA

HEA

HEATING ELEMENT

TING ELEMENT

TING ELEMENT

TING ELEMENT

TING ELEMENT

The heating element is designed to
deliver a predetermined amount of
heat to the cooling unit. To check
a heating element, remove the
heater leads from the printed
circuit board and measure for
proper resistance across the
two leads with a properly
calibrated ohm meter. This
check is to be done with the
heating element at room temperature. The proper ohms
for RM3604 is 48 and RM3804 is 44 with a tolerance of
ten percent. If the resistance is outside the tolerance
range, replace the heating element.

SECTION 3

SECTION 3

SECTION 3

SECTION 3

SECTION 3

DC 

DC 

DC 

DC 

DC V

V

V

V

VOL

OL

OL

OL

OLT

T

T

T

TA

A

A

A

AGE REQ

GE REQ

GE REQ

GE REQ

GE REQUIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

UIREMENTS

For the refrigerator to operate on any mode, DC voltage
must be supplied to the terminals at the rear of the
refrigerator and must be connected directly to the battery
of the RV. The operational range is 10.5 to 15 volts DC.
Connecting the refrigerator to an unregulated converter
can result in improper operation of the refrigerator. Do not
use the body or chassis of the RV as a substitute for
either of the two conductors. Proper polarity is crucial for
operation of the refrigerator. Check for proper voltage at
the positive and negative terminals at the back of the
refrigerator. If power is outside the operational range,
correct the power supply problem. The power supply to
the refrigerator must be fused. Maximum fuse size: 25
amp for RM3604 and RM3804.

3-PRONG PLUG
FOR 120V AC

FUSE LINK
3AMP

MANUAL GAS
SHUTOFF VALVE

IGN.
LOCK

COVER

TERMINAL
BLOCK

With the refrigerator operating on AC or gas mode, if
voltage to the refrigerator slowly drops to or below 9.5
volts DC, the gas flame will come and will not be thermo-
stat controlled. Low DC volts (below 9.5) could cause
over-cooling.

SECTION 4

SECTION 4

SECTION 4

SECTION 4

SECTION 4

DC COMPONENTS

DC COMPONENTS

DC COMPONENTS

DC COMPONENTS

DC COMPONENTS

4.1

4.1

4.1

4.1

4.1

HEATING ELEMENT

HEATING ELEMENT

HEATING ELEMENT

HEATING ELEMENT

HEATING ELEMENT

The heating element is
designed to deliver a
predetermined amount of
heat to the cooling unit.
Check the heating
element with ohms
resistance using a prop-
erly calibrated ohm meter.
This check is to be done
with the element at room
temperature. The proper ohms for RM3604 and
RM3804 DC heating element is .67 with a tolerance
range of ten percent. If the heating element is
outside this range, replace it.

NOTE

NOTE

NOTE

NOTE

NOTE:  It will take a very precise ohm meter to
accurately read this measurement. If a precise ohm
meter is not available, a continuity reading will
indicate an open or complete circuit. If an open
circuit is the test result, replace the element.

4.2

4.2

4.2

4.2

4.2

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

The thermostat operates on DC volts and regulates the
inside refrigerator temperature on all modes, by
making and breaking the circuit to the printed circuit
board. The internal mechanism breaks contact (conti-
nuity) when adequate cabinet temperature has been
reached. Check the thermostat for continuity. This
check should be made at room temperature with the
thermostat turned all the way to MAX. Another check
would be to use a jumper wire with insulated clips and
bypass the thermostat.

NOTE

NOTE

NOTE

NOTE

NOTE:  Use care when doing this test. Do not short to
thermostat casing. Also remove jumper after testing is
completed.

If the above test allows the refrigerator to operate and/
or the continuity test proves the thermostat to be
defective, replace the thermostat. A defective thermo-
stat would cause insufficient cooling, no cooling and
freezing on all modes.

4.3

4.3

4.3

4.3

4.3

SOLENOID VALVE

SOLENOID VALVE

SOLENOID VALVE

SOLENOID VALVE

SOLENOID VALVE

The solenoid valve assembly is a safety valve

safety valve

safety valve

safety valve

safety valve as well as

gas flow valve

gas flow valve

gas flow valve

gas flow valve

gas flow valve. When the AES selects LP gas opera-

tion, DC volts are sent to the solenoid coil which opens
the internal valve.

Summary of Contents for RM3604

Page 1: ...Foreword Foreword This service manual is the result of the dedication of The Dometic Corporation and its engineers in giving service people the necessary instruction for making accurate analyses of c...

Page 2: ...it Board Switch Card 4 1 1 Fuse 9 SECTION 5 LP GAS REQUIREMENTS _ _ 10 SECTION 6 LP GAS COMPONENTS 6 1 Manual Shut Off Valve _ _ _ _ 10 6 2 Orifice 10 6 3 Thermocouple ___ _ _ __ __ _ _ 10 6 4 Burner...

Page 3: ...Upper Circuit Board 4 9 2 12 Circuit Board 4 10 5 AC Volts 1 Heating Element 2 Upper Circuit Board 4 9 2 5 Wiring 7 2 Thermostat 4 2 Circuit Board 4 10 2 DC Volts 3 1 Heating Element 4 1 Upper Circuit...

Page 4: ...14 Flame failure light after 3 minutes 15 Interior Light ON when door is closed 16 Rapid formation of frost AC Volts 1 Heating Element 2 DC Volts 3 Heating Element 4 1 Wiring 7 2 LP gas 5 1 Orifice 6...

Page 5: ...Maximum fuse size 25 amp for RM3604 and RM3804 3 PRONG PLUG FOR 120V AC FUSE LINK 3AMP MANUAL GAS SHUTOFF VALVE IGN LOCK COVER TERMINAL BLOCK With the refrigerator operating on AC or gas mode if volta...

Page 6: ...With the igniter producing spark connect meter leads to L and ground terminals on the igniter with the meter set on 20 volts DC range or lower The meter should read a pulsating voltage If not replace...

Page 7: ...ld be off When the refrigerator door is open the switch is closed interior light should be on Check that the switch assembly is properly aligned and that it is not broken Check the switch assembly for...

Page 8: ...turned to ON With the AES function switch manually With the AES function switch manually With the AES function switch manually With the AES function switch manually With the AES function switch manual...

Page 9: ...ion switch With the gas function switch With the gas function switch With the gas function switch With the gas function switch NOT depressed NOT depressed NOT depressed NOT depressed NOT depressed A r...

Page 10: ...amp and Switch NOTE The following checks should be made on the upper circuit board and harness assembly BEFORE replacing the upper circuit board or wiring harness The checks are to be done with the wi...

Page 11: ...from meter If no voltage is present replace the circuit board If voltage is present the circuit board is NOT defective do not replace BLACK 6 Pin RED 6 Pin 4 THESE PROCEDURES MUST BE FOLLOWED IN SEQUE...

Page 12: ...for a few moments while depressing the safety valve Remove the flame and release the safety valve The valve should hold for at least 30 seconds If it does not hold the safety valve open for 30 second...

Page 13: ...te capacity to avoid voltage drop The wire gauge should be chosen with consideration to the wire length in accordance with the Table below MAXIMUM CONDUCTOR WIRE LENGTH IN FEET MAXIMUM CONDUCTOR WIRE...

Page 14: ...F CIRCUIT BOARD TERMINALBLOCK HEATER CONNECTOR MAIN SWITCH DOOR SWITCH LIGHT THERMOSTAT GAS VALVE COIL THERMOCOUPLE REIGNITER TIME FUSE 3 3 15 AMP GAS FLAME WARN LAMP GAS FUNCTION SWITCH GAS FUNCTION...

Page 15: ...eve proper air flow All potential dead air pockets should be blocked or baffled to insure that heat won t be trapped in these spaces and reduce efficiency In addition the cooling unit should be at lea...

Page 16: ...tainers of water Next supply 115 volts direct to the AC heating element and operate for at least 12 hours Then check the temperature on the thermometer It should be at 45 degrees or lower depending on...

Reviews: