9
Switching over / time delays
There are some built-in time delays when switching between power supply options.
Refuelling stop
: In order to prevent unintended switching to gas operation
during refuelling, the AES electronic system starts gas operation of the refrigerator,
after the motor has been turned off for 15 min.
The use of naked flames is prohibited in petrol station environments.
If the refuelling stop lasts longer than 15 min., the refrigerator should be
switched off at the main switch (A).
Undervoltage operation
If the electrical supply voltage in 230V or 12V operation is not sufficient to maintain the
cooling function, the AES switches to gas operation.
This state is signalled by the undervoltage LED (C, yellow) lighting up. If gas operation
is selected due to undervoltage, the refrigerator remains in gas
operation for 30 min., in order to prevent
continual switching back and forth between
power modes. After 30 min. of gas opera-
tion, the electronic system checks the avai-
lable voltage at regular intervals. If the
supply voltage is sufficient again, the
refrigerator switches back to 230V or 12V operation as the case may be.
Switching off
5.2.7
5.2.8
5.3
230V
Gas
12V
immediate
immediate
immediate
approx. 20sec.
15 min. (cf. refuelling stop)
approx. 20sec.
C
1. Set main switch (A) to
the off position.
Switching off gas operation!
If the refrigerator is to be taken out of service for an extended period of
time, the on-board shut-off valve and the cylinder valve must be closed.
2. Secure the door open by
means of the door stop.
The door will be slightly
ajar.
Summary of Contents for RM6275L
Page 17: ...17 Declaration of conformity 5 19 ...
Page 27: ...27 Wiring diagram 6 9 3 ...