2. CONTROL PANEL

LEGEND 2-WAY AES MODEL

1. Main Power Button ON/OFF
2. AES Mode Selector Button
3. Temperature Selector Button

A. AC Mode Indicator Lamp
B. AES Mode Indicator Lamp
C. GAS Mode Indicator Lamp
D. CHECK Indicator Lamp

(GAS Mode Only)

E. Temperature Indicator Lamps
F. Climate Control Switch

ON

OFF

AC

GAS

1

2

 COLD 1      2      3     4      5  COLDEST

3

C

F

FIG. 9

B

A

D

E

CHECK

2-WAY AES DISPLAY PANEL

3. OPERATING INSTRUCTIONS

A. A 12 volt DC supply must be available for the electronic

control to function.

B. Press the main power ON/OFF button (1) to the DOWN

position.

C. Press the TEMPERATURE SELECTOR BUTTON (3) 2-

Way Model, until the lamp at the desired setting is
illuminated.

2-WAY AES DISPLAY PANEL

ON

OFF

AUTO

AC

GAS

1

2

CHECK COLD 1     2     3     4      5  COLDEST

3

D

C

B

E

F

B

A

C

D

E

D. AES MODE

1. Move the AES/GAS mode selector button (2) to the

DOWN position. (If 120 volts AC is available, the AC
mode indicator lamp (A) will illuminate indicating AC
operation. If 120 volts AC is not available, the GAS mode
indicator lamp (C) will illuminate and the control system
will automatically switch to GAS operation.

2. If the CHECK indicator lamp (D) illuminates and the GAS

mode indicator lamp (C) is off, the controls have failed to
ignite the burner in the GAS mode. GAS operation may
be reset by pressing the main power ON/OFF button (1)
to the OFF then ON position. (See Step 2, under GAS
MODE).

3. Press the TEMPERATURE SELECTOR button (3) until

the lamp at the desired position is illuminated.

4. When operating in the AES mode, the AES mode

indicator lamp (B) will illuminate. The control system will
automatically select between AC and GAS operation
with AC having Priority over GAS. Either the AC indicator
lamp (A) or the GAS indicator lamp (C) will illuminate
depending on the energy source selected by the control
system. If the control system is operating with AC energy

Summary of Contents for RM7030

Page 1: ...WARNING Improper installation adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual For assis tance or additional information consult a qualified installer service agency or the gas supplier AVIS Cet appareil doit être réparé seulement par un réparateur autorisé Modification de l appareil pourrait être extrèmement dangeruse et pourrait causer mal ou...

Page 2: ...owever contingentontheinstal lation being made in accordance with the following instruc tions as applicable In the U S A the installation must conform with 1 National Fuel Gas Code ANSI Z223 1 latest edition 2 ManufacturedHomeConstructionandSafetyStandard Title 24 CFR Part 3280 3 Recreational Vehicles ANSI A119 2 latest edition The unit must be electrically grounded in accordance with the National...

Page 3: ...ator NOTE Clearance N isthedistancebetweenthebottom of the lower vent to the roof material For ventilation height refertoSectionA Installation Item5 Ventilation Heights See FIG 2 FIG 2 e Refrigerator Overall Installation Recess Model Dimensions Dimensions Dimensions RM7030 Height Width Depth Height Width Depth Height Width Depth A B C h w d H W D Inches 58 3 4 33 1 2 23 5 8 57 1 8 32 3 8 22 5 8 57...

Page 4: ...he appliance s combustion system from the vehicle interior NOTE Becarefulnottodamagethesealingstripappliedto theflooroftheenclosurewhentherefrigeratorisputinplace The refrigerator is secured in the enclosure with six screws and they must be installed in the following order First Two Screws installed on front base Second Two Screws installed in the top frame Third Two Screws installed in the rear b...

Page 5: ...le Cover Drain W ater Hose Flexible Cord FIG 6 When testing the gas supply system at test pressures in excess of 1 2 psig the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system When testing the gas supply system at pressures less than orequalto1 2psig theappliancemustbeisolatedfromthe gas supply piping by closing its individual manual shutoff valve...

Page 6: ... PANEL The refrigerator is normally delivered without the door pan els Before starting the mounting work check that the panel dimensions are in compliance with those given in the Table on Page 7 and the instructions are read thoroughly When mounting the panel proceed as follows See FIG 8 NOTE If raised door panels are going to be used be 1 1 1 2 1 1 6 4 3 5 1 FIG 8 suretheconsumercanproperlyoperat...

Page 7: ...ectionsoftheevaporator tubing This will slow the circulation of hydrogen and ammo nia gas or in severe cases completely block it resulting in a loss of cooling Any time the vehicle is parked for several hours with the refrigerator operating the vehicle should be leveled to pre ventthislossofcooling Thevehicleneedstobeleveledonly so it is comfortable to live in no noticeable sloping of floors or wa...

Page 8: ...tor button 2 to the DOWN position If 120 volts AC is available the AC mode indicator lamp A will illuminate indicating AC operation If120voltsACisnotavailable theGASmode indicator lamp C will illuminate and the control system will automatically switch to GAS operation 2 IftheCHECKindicatorlamp D illuminatesandtheGAS mode indicator lamp C is off the controls have failed to ignite the burner in the ...

Page 9: ... the frozen food storage compartment provided they are precooled first in the refrigerator They can be stored about three times longer in the frozen food compartment as compared to the fresh food compartment To prevent food and it then becomes unavailable the system will auto matically switch to GAS As soon as AC becomes availableagainthecontrolwillswitchbacktoACregard less of the status of GAS op...

Page 10: ...rong chemicals or abrasives to clean these parts as the protective surfaces will be damaged It is important to always keep the refrigerator clean F SHUT OFF STORAGE PROCEDURE ShutofftherefrigeratorbypressingthemainpowerON OFF button to the UP OFF position Iftherefrigeratorwillnotbeinoperationforaperiodofweeks it should be emptied defrosted cleaned and the doors left ajar The ice tray should also b...

Page 11: ...nder the freezer to ON The climate control can be left on continuously or only used when temperatures require it NOTE The climate control will draw 12 volts DC power continuously when in the ON position It should be turned OFF when a charging source is not available Most LP gas appliances used in recreational ve hiclesareventedtotheoutsideofthevehicle When parkedclosetoagasolinepump itispossibleth...

Page 12: ...wer start stop the engine etc Compare the operation with the operation described in Section C Operation Instructions F FUSES The 2 way AES model is equipped with 2 fuses one for the refrigerator control system and one for the AC cartridge heater See Table below To replace fuse s proceed as follows 1 Disconnect the wall plug and the 12 volt wires 2 Remove the power module cover See FIG 6 3 Snap the...

Page 13: ...operly before starting the ice maker The refrigerator has to be connected to120voltsACbeforetheicemakercanoperate Thewater line manual shutoff valve must be open To start the ice making move the ice level bail arm to down position see FIG 12 To shut off the ice making move the ice level bail arm to fully up position see FIG 12 Whentheicemakerthermostatsensesthepresettempera tureforejectionoftheice...

Page 14: ...E 5A FUSE 3A SWITCH HEATING CA BLE R Q M LIGHT U RETAINER F OR TERMINAL BL OCK TERMINAL BL OCK S T CIRCUIT BOA RD P OWER 5 6 GREY BROWN 7 BLUE GREEN GREEN YELLOW 3 4 BLACK WHITE 2 1 Q 6 TROUBLESHOOTING Ice Maker Fails Does Not Make Ice A Check fuses or breaker supplying 120 volts AC to refrigerator and check that RV is connected to power B Check that ice level bail arm is in down position C Check ...