Troubleshooting
29
WARNING type fault messages
All faults messages of the WARNING type are reset automatically once the fault has
been rectified.
ERROR type fault messages
All faults messages of the ERROR type must be reset manually:
➤
Press the
button
for 2 seconds.
✔
A beep sounds.
✔
The error has been reset.
Code
Fault
Solution
Defective temperature sensor in the
refrigerator compartment
Contact customer service for assistance.
AC power not connected or AC volt-
age < 190 V
Connect the refrigerator to AC or select a
different energy type, e.g. gas or DC.
DC power not connected
Connect the refrigerator to DC or select a
different energy type, e.g. gas or AC.
DC overvoltage (> 16 V)
Reduce the DC supply voltage.
Tank stop mode: Gas operation is
blocked for 15 minutes.
Wait 15 minutes or switch to another
operating mode.
Beep
The door is opened for more than
2 minutes.
Close the door.
Code
Fault
Solution
No connection between power
module and display
Contact customer service for assistance.
No cooling in gas mode
Check if the device is tilted and level it if
necessary.
Reset the error.
Contact customer service if this error occurs
again.