EN
RMD10
Connecting the refrigerator
23
Always use a backup wrench when connecting the gas supply line to the gas
inlet fitting.
➤
Have a leak test and a flame test performed by an authorized specialist after
professional installation.
Ensure you are issued with a certificate of inspection and hand this certificate to
the end user for safekeeping.
Instructions for the authorized specialist:
➤
Check all connections for gas leaks with soap and water.
➤
Do not
use a naked flame for detecting leaks.
➤
Ignite the burner to ensure correct operation of gas valve, burner and ignition.
➤
If the device fails to operate correctly after all checks have been carried out, refer
to the authorized service provider in your area.
Conditions for the gas supply
➤
Ensure the following:
The gas supply system must incorporate a pressure regulator to maintain a
supply pressure of max. 13.5 inches water column, static (no load).
➤
Disconnect the refrigerator and its shut-off valve from the gas supply before test-
ing the gas supply system, if test pressures are higher than 0.5 psig.
➤
Isolate the refrigerator from the gas supply by closing its manual shut-off valve
before testing the gas supply system, if test pressures are lower than 0.5 psig.
5.2
Connecting to DC and AC
A
NOTICE!
The electrical installation and repairs must only be performed by a spe-
cialist in accordance with the applicable regulations and standards.
RMD10_INM_US.book Seite 23 Dienstag, 10. Dezember 2019 2:09 14
Summary of Contents for RMD10
Page 5: ...RMD10 5 300 mm 11 81 in 1 2 6 RMD10_INM_US book Seite 5 Dienstag 10 Dezember 2019 2 09 14...
Page 8: ...RMD10 8 0 a 1 2 3 b 1 2 c d RMD10_INM_US book Seite 8 Dienstag 10 Dezember 2019 2 09 14...
Page 9: ...RMD10 9 e f 1 2 g 2 1 3 h RMD10_INM_US book Seite 9 Dienstag 10 Dezember 2019 2 09 14...