EN
RMDX21, RMDX25
Troubleshooting
35
The refrigerator does
not cool sufficiently.
The ventilation around the
cooling unit is not sufficient.
Check that the ventilation grille is
not obstructed.
The evaporator is iced up.
Check whether the refrigerator
door is properly closed. Defrost
the refrigerator.
The temperature is set too
high.
Set a lower temperature.
The ambient temperature is
too high.
Remove the ventilation grille for a
while so that warm air can escape
quicker.
Too much food at once was
placed in the refrigerator.
Remove an item.
Too much warm food at once
was placed in the refrigerator.
Remove the warm food and leave
it to cool down before putting it in
again.
The refrigerator has not been
operating for very long.
Check the temperature again after
four or five hours.
Problem
Possible cause
Suggested remedy
RMDX21-25--O-AU.book Seite 35 Freitag, 3. Februar 2017 5:10 17