EN
Maintenance
RMLT94xx
40
➤
Wipe the refrigerator and oven dry with a cloth after cleaning.
➤
Check the condensate drain regularly.
Clean the condensate drain when necessary. If it is blocked the condensate
collects on the bottom of the refrigerator.
➤
Make sure that the ventilation grille and the roof vent (fig.
v
, page 11) on the
refrigerator-oven combination are free of any dust and dirt, so that heat can be
released and the refrigerator-oven combination is not damaged.
11
Maintenance
!
I
➤
Have the gas system and connected flues inspected before initial operation and
then every two years by an authorised professional to ensure they comply with
the European standard EN 1949.
➤
The gas burner must be cleaned of impurities whenever necessary or at least
once a year. When using LPG (tank or refillable cylinders), the maintenance inter-
val is reduced to twice or four times a year, depending on the degree of contam-
ination. This can be determined by a reduced cooling capacity in gas mode.
➤
Keep a record of any maintenance performed on your refrigerator.
WARNING!
Working on gas and electrical installations may only be performed by
qualified technicians.
NOTE
Have the refrigerator checked if the vehicle has not been used for a long
time. To do this, contact the customer service.
RMLT94xx-O-West.book Seite 40 Montag, 24. Juli 2017 1:15 13