EN
RPD190, RPD 218
Troubleshooting
33
Poor cooling, increase in interior temperature
Water in or under the refrigerator
Unusual noises
Fault
Possible cause
Remedy
Compressor runs for a
long time/continuously
Evaporator is iced over.
Defrost the evaporator.
Cooling area insulation is insufficient
(moist/wet).
Adjust/replace the door
seal.
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location.
Condenser is dirty.
Clean the condenser.
Fan defective
Replace the fan.
Compressor does not
run often
Battery capacity exhausted
Charge the battery.
Fault
Possible cause
Remedy
Water is leaking into the
inside of the
refrigerator.
The water drain system is clogged.
Clean the drain.
Foodstuffs are preventing the water
from flowing to the drain tube.
Make sure that foodstuffs
do not touch the rear
wall.
Water is leaking onto
the floor.
The hose is split or not routed outside
the vehicle.
Check the drain hose at
the rear of the device.
Fault
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (touching the
wall).
Bend the component
carefully away from the
obstruction.
There is a foreign object stuck
between the cooling unit and the
wall.
Remove the foreign
object.
Fan noise (normal)
–
RPD190-218--IO-AU.book Seite 33 Montag, 24. Oktober 2016 5:08 17