Installing the refrigerator
RUA5208X, RUA6408X, RUA8408X
EN
10
• The outer wall must be fitted with one air inlet ventilation grille (fig.
3a, page 9) and one out-
let ventilation grille (fig.
3b, page 9) so that the heat generated can be easily released to the
outside:
– Lower air inlet vent LS300 must be installed flush with the lowest opening of the grill flush
with the floor of the refrigerator.
– Upper air outlet vent LS300 must be installed with the bottom of the vent no lower than
equal to the top of the refrigerator cabinet, the bottom of the top vent can be higher than the
cabinet (RUA5208X only: minimum permitted height is 935mm from the bottom of the
refrigerator).
• Fit an air deflection plate (fig.
6, page 9) above the condenser so that the heat does not
accumulate in the vehicle.
• Put insulation wool (fig.
1, page 9) on top and sides of the cabinet.
• If the lower ventilation grille of the air inlet vent cannot be installed flush to the floor, a gas
escape hole (fig.
, page 16) must be provided in the floor for releasing
any possible gas leakage.
• The distance between the refrigerator and the rear wall must be at least 10 mm and at most
25mm.
Description
1
Insulation wool on top and sides of cabinet
2
Clearance minimum 10mm to maximum 25mm
3
LS 300 ventilation grille
4
Height is equal to the height of the cabinet
Note:
If the vehicle‘s design does not allow you to have the cabinet
wholly below the bottom of the top exhaust vent then, the bottom of the
condenser fins should be no further than ½ way up the top exhaust vent.
4a
Air deflection plate must be installed to direct airflow into the condenser
fins if top vent height is lower than the top of the refrigerator cabinet.
5
Dometic gas flue kit 3776
6
Air deflection plate
7
Gas escape hole, min. 40 mm – required if lower air vent would not permit
all leaked gas to escape
DometicRUA5208X6408X8408X_INM_4445102444_APAC(en)_xxxx-xx-xx.book Seite 10 Montag, 15.