background image

Installing the refrigerator

RUA5208X, RUA6408X, RUA8408X

EN

12

• The recommended maximum distance between the refrigerator and the rear wall is 25 mm. A 

distance of more than 25 mm between the refrigerator and rear wall leads to poor performance 
and increases the power consumption of the refrigerator. Reduce the space behind the refrig-
erator to maximum 25 mm to create adequate air inlet and outlet ventilation corridor . Use a 
ventilation plate (fig.

4

1, page 11 and fig.

5

1, page 11), for example, to achieve this.

Installation with one lower side vent and one roof vent

RUA 5208X

RUA 6408X,  RUA 8408X

5

3

4

1

2

5

6

6

3

4

1

2

7

7

6

DometicRUA5208X6408X8408X_INM_4445102444_APAC(en)_xxxx-xx-xx.book  Seite 12  Montag, 15. 

Summary of Contents for RUA 6408X

Page 1: ...RUA 5208X RUA 6408X RUA 8408X Absorption refrigerator Installation Manual EN REFRIGERATION RU DometicRUA5208X6408X8408X_INM_4445102444_APAC en _xxxx xx xx book Seite 1 Montag 15 N...

Page 2: ...ign law The underlying technical design and the products contained herein may be protected by design patent or be patent pending The trademarks mentioned in this manual belong to Dometic Sweden AB All...

Page 3: ...ein may result in an injury to yourself and others damage to your product or damage to other property in the vicinity This product manual including the instructions guide lines and warnings and relate...

Page 4: ...he type plate Only use pressure controllers with a fixed setting which comply with national regulations Dismantle all refrigerator doors for the disposal of the old refrigerator and leave the shelves...

Page 5: ...8 Never pull the plug out of the socket by the connection cable The refrigerator must not be exposed to rain DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE 3 Scope of...

Page 6: ...hese instructions This manual provides information that is necessary for proper installation and or operation of the product Poor installation and or improper operating or maintenance will result in u...

Page 7: ...e the following Ensure that the floor is solid and level Ensure that the refrigerator is level The refrigerator must be installed so that it is easily accessible for service work easy to remove and in...

Page 8: ...ig 2 page 8 RUA5208X RUA6408X RUA8408X Refrigerator Overall dimension in mm Height A 1191 1447 1657 Width B 550 550 550 Depth C excludes control knob 5mm 677 677 677 Recess Dimension in mm Height H 11...

Page 9: ...t it is protected from excessive heat as this leads to poor perfor mance and increases the power consumption of the refrigerator The electrical installation must comply with national and local regulat...

Page 10: ...ion grille of the air inlet vent cannot be installed flush to the floor a gas escape hole fig 3 7 page 9 and fig b page 16 must be provided in the floor for releasing any possible gas leakage The dist...

Page 11: ...A5208X RUA6408X RUA8408X Installing the refrigerator EN 11 10 25 25 25 RUA5208X 1 4 RUA6408X RUA8408X 10 25 25 25 1 5 DometicRUA5208X6408X8408X_INM_4445102444_APAC en _xxxx xx xx book Seite 11 Montag...

Page 12: ...ses the power consumption of the refrigerator Reduce the space behind the refrig erator to maximum 25 mm to create adequate air inlet and outlet ventilation corridor Use a ventilation plate fig 4 1 pa...

Page 13: ...ion wool fig 6 1 page 12 on top and sides of the cabinet If the lower ventilation grille of the air inlet vent cannot be installed flush to the floor a gas escapehole fig 6 7 page 12 andfig b page 16...

Page 14: ...ng space Gas powered refrigerators in caravans or motor homes must be installed in a sealed location This means that the combustion air can not be extracted from the interior and exhaust fumes are pre...

Page 15: ...tor into position step 2 in fig 8 page 14 and fig 9 page 15 This then seals the space behind the refrigerator to the interior of the vehicle OPTIONAL If the refrigerator stands on a platform install t...

Page 16: ...m getting inside while driving fig b page 16 If you have to use a roof vent instead of an upper wall vent Cut out a section in the roof Refer to the roof vent instruction manual for the required dimen...

Page 17: ...stallation is water resistant fig d page 17 2 Insert the installation frame and screw it down tightly fig e page 17 Use all fixing holes No in fig c Description 1 Slider 2 Ventilation grille 3 Install...

Page 18: ...1 and step 2 in fig f page 18 4 Insert the slider and lock the ventilation grille with it step 3 in fig f page 18 6 6 Install the roof vent No in fig g Description 1 Hood 2 Installation frame f 1 2 3...

Page 19: ...is water resistant fig h page 18 2 Insert the installation frame and screw it down tightly fig i 1 page 20 Use all the fixing holes for this 3 Insert the hood and screw it down tightly fig i 2 page 20...

Page 20: ...sumption of the refrigerator If a flue extension is used it must have no more than 2 bends have minimum rise of 35 degrees above horizontal be as short as practicable designed to prevent leaks and be...

Page 21: ...e flue pipe fig j 8 page 20 of the refrigerator 4 Direct the T piece at an angle of 45 towards the rear wall 5 Attach the T piece adaptor and flue pipe with a screw fig j 6 page 20 6 Install the mount...

Page 22: ...the refrigerator RUA5208X RUA6408X RUA8408X EN 22 9 Attach the cover for the flue stack outside on the vehicle fig m page 22 m DometicRUA5208X6408X8408X_INM_4445102444_APAC en _xxxx xx xx book Seite 2...

Page 23: ...ic bushes in the sides of the refrigerator and fasten into the recess walls 3 Fit the caps fig n 2 page 23 into the bushes CAUTION Only screw through the bushes built into the refrigerator otherwise f...

Page 24: ...the gas supply by a specialist in accord ance with the applicable guidelines and standards Only use cylinders of universal LPG gas fitted with an approved gas pressure regu lator Compare the pressure...

Page 25: ...heating element must be made to the vehicle engine battery connection only while engine is running fig p page 25 NOTE The mains socket must be readily accessible so that you can unplug the power cord...

Page 26: ...RUA8408X HV AC IN AC OUT 12VDC PV LED LED DISPLAY HRLY CIB S232 NTC2 NTC1 GVAL 87 85 86 30 8 D 10 10 1 2 5 4 3 6 7 8 12 11 9 10 13 14 17 21 20 22 24 19 18 23 26 27 25 16 15 RUA6408X RUA8408X q Dometi...

Page 27: ...10 Power module 11 Control button 12 Display 13 Inner fan 14 LAC and defrost heater 15 Frame heater RUA6408X RUA8408X only 16 Gas valve 17 Temperature sensor 18 Lamp 19 Door sensor 20 Gas inlet 21 12...

Page 28: ...page 25 4 Connect vehicle battery cables to the respective plus and minus terminal fig q 23 page 26 5 Connect house battery cables to the respective plus and minus terminal fig q 26 page 26 D In auto...

Page 29: ...Power can only be supplied if the engine is running No house battery recharging from the vehicle The D connection is bridged to the vehicle battery connection fig q 23 page 26 House Battery Anderson...

Page 30: ...n is via the house battery House battery recharged by vehicle The D is turned on and off via the optional fridge movement switch Fridge Switch Vehicle Anderson plug must be controlled by ignition rela...

Page 31: ...kaging material in the appropriate recycling waste bins wherever possible M Consult a local recycling center or specialist dealer for details about how to dispose of the product in accordance with the...

Page 32: ...OCAL DEALER dometic com dealer YOUR LOCAL SUPPORT dometic com contact dometic com 1 01 1 0 4 0 1 1 2 2 1 2 9 0 DOMETIC GROUP AB 3E 0 1 4 4445102444 2021 11 15 DometicRUA5208X6408X8408X_INM_4445102444_...