Smart Touch Cabin Control Installation & Operations Manual
OPERATION
L-3380 ENGLISH
21
Figure 41: Smart Touch Faults
History Page 1 of 1
1.
Fault History Allows the user to view the history of previously cleared faults
and the current active faults.
NOTE: To view the cleared faults, hold CLR button 10 seconds.
Figure 42: Smart Touch Compressor
Run Hours View
2.
Compressor Run Hours Allows the user to see the current amount of hours
the compressor has run. The value can be cleared by pressing the CLR icon.
NOTE: To view the cleared faults, hold CLR button 10 seconds.
Figure 43: Smart Touch Fan
Run Hours View
3.
Fan Run Hours Allows the user to see the current amount of hours the fan
has run. The value can be cleared by pressing the CLR icon.
NOTE: To view the cleared faults, hold CLR button 10 seconds.
When used with optional electric heat, the fan remains on for 4 minutes after the
heater cycles off even if fan is set to cycled operation.
Q
UICK
-S
TART
O
PERATIONS
C
HECKLIST
1.
Ensure seawater-intake ball valve (seacock) is open.
2.
Make sure the control is powered OFF.
3.
Turn on the air conditioner circuit breaker. If the seawater pump has its own circuit breaker, turn that on also.
4.
Turn the control ON.
5.
Press the Fan icon. Verify that the fan is running and that there is steady airflow out of the supply-air grille.
6.
Select a temperature set point lower than the current cabin temperature. This starts the compressor and seawater
pump.
7.
Check for a steady solid stream of water from the overboard discharge.
8.
Verify that there is steady airflow out of the supply-air grille.
If the unit does not appear to be operating properly, refer to the guidelines in “TROUBLESHOOTING” on page 27.
NOTICE
Do not turn the unit off and then immediately turn it back on. Allow at least 30 seconds for refrigerant
pressure to equalize.