background image

Single Stage Chillers

Tube-and-Shell Chillers

Custom Multi Stage Chillers

MTS480

Two 20-ton MTS

units on standard

base and frame.

Capacity

Voltage/Cycle/Phase

480,000 BTU/hr

380/50/3

STS540(001)SEH

Three 15-ton units with tube-and-shell 
condensers on a custom base and frame.

Capacity

Voltage/Cycle/Phase

540,000 BTU/hr

230/60/3

TWC36C

The TWC chiller cools and heats, 
and is currently available in 24K, 
30K, and 36K BTU/hr sizes.

Capacity

Voltage/Cycle/Phase

36,000 BTU/hr

All standard voltages.

MCWLP

The modular MCW Low Profile 
is available in 36K to 72K BTU/hr 
models in a height-saving design.

Capacity

Voltage/Cycle/Phase

72,000 BTU/hr

All standard voltages.

MCW

The modular MCW is available in 
capacities from 24K BTU/hr to 180K 
BTU/hr.

Capacity

Voltage/Cycle/Phase

180,000 BTU/hr All standard voltages.

TWC3X2.5HC–CS–TWLC

Three 2.5-ton TWC units on a 
standard base.

Capacity

Voltage/Cycle/Phase

90,000 BTU/hr

230/60/1

s

FMTC5X5HD-407

Five 5-ton MTC units painted 
Japanese Coast Guard green.

Capacity

Voltage/Cycle/Phase

300,000 BTU/hr

230/60/3

s

s

MCW192

Four 4-ton MCW units mounted on a 
standard base.

Capacity

Voltage/Cycle/Phase

192,000 BTU/hr

230/60/3

s

MCW480(009)SCL

Four 10-ton MCW cool-only units on 
a custom vertical frame.

Capacity

Voltage/Cycle/Phase

480,000 BTU/hr

208/60/3

s

s

s

s

FMTC55VDC-407

Two 5-ton MTC units on a vertical 
frame.

Capacity

Voltage/Cycle/Phase

120,000 BTU/hr

230/50/3

s

FMTCLP6X5VDC

Six 5-ton MTC low profile modules 
on a custom frame.

Capacity

Voltage/Cycle/Phase

360,000 BTU/hr

230/60/3

s

s

s

FMTC4X5.5HECK

Four 5.5-ton units on a standard 
base with bolt-on frame.

Capacity

Voltage/Cycle/Phase

264,000 BTU/hr

230/60/3

s

MCW540(002)SEHN

Three 15-ton MCW cool-only units 
on a custom frame.

Capacity

Voltage/Cycle/Phase

540,000 BTU/hr

460/60/3

s

4

5

Dometic’s 

Pump  Packages

  conveniently  reduce  the 

installation  time  of  chilled-water  systems  by  combining 
several necessary components in one package.

   Includes pump, expansion tank, dual-scale (psi/kPa) 

pressure gauge, and fill assembly.

   Bladder-style expansion tank relieves water pressure 

to prevent leaks.

   Dual-scale pressure gauge is convenient for US and 

international customers.

Our 

Variable  Frequency  Drive

  eliminates  the  large 

starting in-rush of current of the compressor by ramping 
up voltage and frequency in a controlled time period.

   208/230V 3-phase output with 1-phase or 3-phase 

input.

   Full 60Hz capacity even at 50Hz input (230V only).

   400/480V 3-phase models available.

AT-MU air handlers

 are designed for use in fresh air 

make-up systems where outside air is drawn in by the 
air handler, cooled, dehumidified, and reheated to room 
temperature, then ducted to various areas.

   Compact design with vibration isolation mounts.

   Electric heat with 2-stage electric heat overload.

   Integrated 3-way bypass valve.

Accessories  for  improved  efficiency  of  chilled  water  AC 
systems.

   The 

Spirovent

 bleeds the entire system of excess air.

   The 

Back-flow Preventer

 protects fresh water from 

contamination.

   The Pressure Regulator protects the loop water 

from high-pressure damage.

World’s Broadest Selection and Variety of Chilled Water Systems  and Accessories for SuperYachts

All Chillers Available 

In 60Hz or 50Hz

E

N

V

IR

O

N

ME

NTALLY RE

SP

O

N

SI

B

L

E

E

N

V

IR

O

NM

ENT

ALLY RES

PO

N

SIB

LE

All Units

Available

With Green

Gas

Reviews: