EN
Servicing the generator
TEC29EV
24
10.4
Changing the oil (fig.
6
, page 5)
!
A
You may use the following oil:
API SG or SF grade oil for four-stroke engines.
SAE 10W-30 grade oil (can be used at any temperature).
Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-
site.
Change the oil as follows:
➤
Allow the generator to run until warm so that the oil can drain off faster and
completely.
➤
Place a suitable receptacle under the drain plug (
1
).
➤
Take out the drain plug (
1
).
✓
The oil drains off.
➤
Pour fresh oil into the nozzle.
The amount of oil is: 0.6 l.
CAUTION!
Hot oil can cause burns.
NOTICE!
Only dispose of used oil at a specialist recycling station and
observe the local laws for environmental protection.