6
Electronics
FFaasscciiaa ppaanneell
D
Diissppllaayy
10:32
220V
DOOR OPEN
BATTERY FAIL
10:32
220V
red LED
(Alarm)
Display
green LED
(Power)
BACK
-
button
MENU
-
button
LEFT, RIGHT, UP, DOWN
buttons
Key switch
ENTER
-
button
10:32
220V
DOOR OPEN
BATTERY FAIL
10:32
220V
temperature
status-, warning- and
alarm-messages
input voltage
current time
battery
Mute-button
E
Elleeccttrriiccaall C
Coonnnneeccttiioonn
• The mains supply voltage of the unit must be
208-220V (±10%) - 60Hz - 1200W.
• Before connecting the unit, check whether the
details on the nameplate in the interior
correspond to local values. The unit must only be
connected to an earthed socket (Protection class
I), IP 22.
• The unit corresponds to category II of IEC 60364-
4-443.
• Before connecting the unit and switching it on for
the first time, allow it to stand for 30 minutes.
• To prevent problems with other electrical
equipment causing this unit to malfunction, it
should be connected to a separate circuit. Never
connect the unit to a single socket with other
electrical equipment by means of a multi-socket.
• Make sure that the plug of the unit is easily
accessible so that if need be it can be easily
disconnected without having to move other
equipment or furniture.
FFuussee // O
Ovveerr--ccuurrrreenntt R
Reelleeaassee
• The equipment is protected against over-current
by means of a circuit breaker located on the left
back side of the equipment.
• During normal operation, a green lamp lights up
inside the switch.
• The equipment does not work, if the circuit
breaker has released or if it has been switched
off.
• If the circuit breaker should have released, try to
switch on again. If the problem persists, please
inform an electrical specialist or the customer
service.