Other functions
Visual and audible alerts
The device is equipped with an LED and a buzzer that allow users to receive visual and audible alerts after each
operation.
Operation
LED
Buzzer
Stand by
Solid red light
-
Digiting the programming mode
Flashing red light
1 beep
Inside the programming mode
Solid orange light
1 beep
wrong operation
-
3 beeps
Exit programming mode
Solid red light
1 beep
Opening / closing of the relay
Solid red light
1 beep
Alarm
Fast blinking red
continuous beeping
Authorizing user
Fingerprints whose ID corresponds to 997 and 998 or the cards / tags whose ID corresponds to 2999 and 3000 can
inhibit the use of other cards / tags or fingerprints to enable / disable the output.
Once the device reads a user autorizzatrice the LED turns red and flashes 4 times.
From that moment the valid users are disabled to control the device until the moment in which another
autorizzatrice user is detected.
At that point the green LED will flash 4 times and will return to normal operation.
Warning
: The exit button can also activate / deactivate the output.
Restoring the factory and storage functions Master Cards
Warning:
This will return the settings to the factory level, do not delete your utilities already enabled, to do that you
need to perform the following operation:
Remove all users
Working description
Keystroke combination
Digiting the programming mode
(Digit master code)
Remove all users
(Digit master code)
Exit programming mode
Warning:
This will delete the "Add Master Card" and "Delete Master Card".
To restore the factory functions is necessary to remove the tension, press the exit button and hold, turn on, wait for
2 beeps, then release the button, to read 2 cards:
-
The first card that the device will read will be assigned the role of "Add Master Card", which will give it the ability
to add other cards.
-
At the second card that the device will read it will be assigned the role of "Master Delete Card", which will give it
the ability to remove already enabled cards.
If you do not want to put Master cards you need to press the exit button for at least 10 seconds before releasing.