background image

29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia

Phone: 02 9554 9600     |     Fax: 02 9554 9433

enquiries@domuslighting.com     |     www.domuslighting.com

Installation Manual

257

mm

Ø117

mm

2X

6x27mm PA4x30mm

2X

139mm

OFF

ON

6mm

Ø88mm

Ø88mm

30mm

Control Knob

SENS

TIME

LUX

1. 

Refit the Cable Anchorage

2. 

Fit main body onto the Backcover. Adjusting the light direction you desired, then tighten the screws. 

3.  Switch the main power on.

Notes for electrician

•  The LED lamp should be wired to its own light switch. 

•  Do not interconnect with other lights on the same switch.

•  Earth connection must be required.

•  Multiple Muro Fittings cannot be wired to a single switching point.

Understanding the controls

Adjusting the duration time: 

The length of time that remains switched on after activation can be 

adjusted from (10±5) seconds to (4±1) minutes. Rotating the TIME 

knob + to - will reduce the duration time.

Note:

 Once the light has been triggered by the PIR sensor any 

subsequent detection will start the timed period again from the 

beginning.