29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
enquiries@domuslighting.com | www.domuslighting.com
Installation Manual
257
mm
Ø117
mm
2X
6x27mm PA4x30mm
2X
139mm
OFF
ON
6mm
Ø88mm
Ø88mm
30mm
Control Knob
SENS
TIME
LUX
1.
Refit the Cable Anchorage
2.
Fit main body onto the Backcover. Adjusting the light direction you desired, then tighten the screws.
3. Switch the main power on.
Notes for electrician
• The LED lamp should be wired to its own light switch.
• Do not interconnect with other lights on the same switch.
• Earth connection must be required.
• Multiple Muro Fittings cannot be wired to a single switching point.
Understanding the controls
Adjusting the duration time:
The length of time that remains switched on after activation can be
adjusted from (10±5) seconds to (4±1) minutes. Rotating the TIME
knob + to - will reduce the duration time.
Note:
Once the light has been triggered by the PIR sensor any
subsequent detection will start the timed period again from the
beginning.