23
9.5
Empty ash box notice
With this function activated, the boiler lets us know when the boiler ash box is full, so that we
proceed with its emptying. The parameter
“Ashtray status”
of
“User Menu”
allows checking the
actual fill level. When it is full, an
"Empty the ashtray"
warning is activated..
By default, the ash box reminder function is supplied activated and is set to indicative fuel
consumption values which, depending on the quality and type of fuel, will have to be adjusted for
each system. Below shows the default number of kilograms at which the boiler notifies you to
empty the ash drawer:
Boiler model
kg
BioClass HM 66
6000 kg
BioClass HM 43
1350 kg
BioClass HM 25
1000 kg
These values must be updated in the models
Bioclass HM 25
and
Bioclass HM 43
, with the values
from the table below and following the instructions in the paragraph “
Ashtray empty notice
” on the
boiler manual.
Boiler model
Kg Pellets
BioClass HM 25
2800 kg
BioClass HM 43
4000 kg
Select
“Ashtray empty warning”
(
) parameter of
“Setup menu”
and press
to access. The value is set by pressing "
+
" and "
-
"
symbols of setting
(19)
. It is possible to deactivate this function by
setting the value of this parameter to "
OFF
".
NOTE:
Each time a new value is set for this parameter, the ashtray must be emptied.
9.6
Manual setting of feed auger calibration
When this parameter is displayed (
) on
"Setup menu"
, press
to
access and set the value desired by pressing "
+
" o "
-
" of setting
(19)
.
The range of values selectable is OFF, 0.500 - 5.000 kg.
9.7
Screen contrast setting
When this parameter of the
"Setup menu"
is displayed, press
to
access and set the value desired by pressing "
+
" o "
-
" of setting
(19)
.
The range of values selectable is 1 - 5.