25
10.1
Feed auger filling
During the commissioning of the boiler, before calibrating the feed auger or if the hopper runs out
of fuel,
it is compulsory
to fill of fuel the feed auger. By means of this parameter the feed auger will
be filled of fuel, process required for a correct boiler functioning.
When
“Feed auger filling”
parameter is displayed (
) on
"Calibration Menu"
, press
to access. SET symbol blinks and
pressing
again it will be activated filling procedure. The feed
auger will be activated and a count up to 15 minutes (maximum)
will be displayed. During the process by pressing
the feed auger
could be stopped at any time and by pressing RESET the filling
procedure could be finished and return to
"Calibration Menu"
at any
time.
To ensure a complete filling of boiler feed auger it is recommended to make a complete 15 minute
procedure of filling, at least once. Follow the steps shown in the following pictures for a correct
filling of the feed auger:
2
4
3
1
5
15 min.
IMPORTANT: It is compulsory to fill each feed auger during the commissioning or when the
hopper runs out of fuel.