background image

 

 

INSTALLATION AND FUNCTIONING 

INSTRUCTIONS 

OIL BURNER 

DOMESTIC 

D-3 / D-4 

This instruction manual includes all the details necessary for the proper installation and use of the burner. 

We thank you for having chosen a 

DOMUSA TEKNIK 

burner

Summary of Contents for Domestic D-3

Page 1: ...D FUNCTIONING INSTRUCTIONS OIL BURNER DOMESTIC D 3 D 4 This instruction manual includes all the details necessary for the proper installation and use of the burner We thank you for having chosen a DOMUSA TEKNIK burner ...

Page 2: ......

Page 3: ...ADJUSTMENT Observe the flame If there is not enough combustion air it will be dark and it will produce smoke which will close the uptake On the other hand if there is too much combustion air the flame will be white or white blue coloured reducing the efficiency and therefore not fulfilling the anti pollution norms Besides the excess of air may difficult the ignition process The flame must be kind ...

Page 4: ... 2 6 DIMENSIONS I G E F H F B A C D L J K DIMENSIONS TABLE DIMENSION A B C D E F F G H I J K L mm 292 265 140 152 215 75 98 290 ø80 205 100 100 ø90 F Domestic D 3 F Domestic D 4 ...

Page 5: ...tion line blocking screw BL Turn the line adjustment screw RL to the right to increase the airflow and to the left to decrease it After the adjustment has been made screw the combustion line blocking screw BL BL RL 3 mm 0 1 9 CORRECT POSITIONING OF IGNITION ELECTRODES To assure a good ignition of the burner Domestic it is necessary to respect the measures shown in the drawing Besides before mounti...

Page 6: ... oil line installations without reductions and with a perfect hydraulic sealed It is highly recommended to use copper pipes Depression of maximum 0 4 bar 30 cmHg must not be exceeded In aspiration installation H Pipes length m in 8 mm in 10 mm 0 0 25 60 0 5 21 50 1 0 18 44 1 5 15 38 2 0 12 26 2 5 10 26 3 0 8 20 3 5 6 16 In charge installation H Pipes length m in 8 mm in 10 mm 0 5 10 20 1 0 20 40 1...

Page 7: ...h 11 8 23 72 47 44 35 58 59 3 kW mmH2O CHAMBER PRESSURE OIL FLOW D 3 D 4 14 OIL FLOW VERSUS NOZZLE AND PUMP PRESSURE GPH 9 Atm Kg h 10 Atm Kg h 11 Atm Kg h 12 Atm Kg h 13 Atm Kg h 14 Atm Kg h 15 Atm Kg h 0 40 1 45 1 55 1 60 1 67 1 75 1 80 1 87 0 50 1 80 1 90 2 00 2 10 2 20 2 27 2 33 0 55 2 00 2 10 2 20 2 30 2 40 2 50 2 60 0 60 2 20 2 30 2 40 2 50 2 60 2 70 2 80 0 65 2 35 2 50 2 60 2 70 2 80 2 90 3...

Page 8: ... LB RP Black Blue 4 EV2 TC TS Ph N B4 S3 T2 T1 N L1 IG F CH LB 7 TP Brown Pre heater 1 2 5 6 8 10 11 12 3 FR TR MB EV1 LB 4 EV2 TC TS Ph N B4 S3 T2 T1 N L1 IG F CH LB 7 B4 Contact of hour counter S3 Contact of blocking lamp TC Control thermostat TS Safety thermostat CH Hour counter IG General switch F Fuse LB Blocking lamp LB External blocking lamp FR Photocell sensor TR Ignition transformer MB Oi...

Page 9: ...nect and disconnect the red oil tube to the combustion line proceed as follows Press the connector o ring in the direction of the arrow shown below and simultaneously pull the red tube PRESS O RING RED PIPE OIL OIL EASY CONNECT RACOR ...

Page 10: ... the form of colour codes see the colour code table below During ignition the indication is as shown in the following table Colour code table for multi colour indicator lights LEDs Status Colour code Colour Wait time tw other standby statuses Off Fuel pre heater on Yellow Ignition phase controlled ignition Flashing yellow Functioning flame OK Green Functioning flame not OK Flashing green External ...

Page 11: ...use Flashes 2 times On No flame established when ignition safety time ends Fuel valves defective or dirty Flame detector defective or dirty Burner maladjustment no fuel Ignition unit defective Flashes 4 times On External light during burner ignition Flashes 7 times On Excessive flame loss during functioning limited number of repetitions Fuel valves defective or dirty Flame detector defective or di...

Page 12: ...teban s n 20730 AZPEITIA 20737 RÉGIL Guipúzcoa Tel 34 943 813 899 Fax 34 943 815 666 www domusateknik com DOMUSA TEKNIK reserves the right to make modifications of any kind to its product characteristics without prior notice CDOC000017 CDOC000017 11 19 ...