Evolution Solar HDX
14
4.4
ø80-125 concentric vertical duct for combustion product evacuation and air intake (type C
33
)
Combustion product evacuation and air intake can be made using concentric Ø80 mm ducts for
combustion product evacuation and Ø125 mm ducts for air intake, using the Ø80-125 vertical duct
kit, code CGAS000231.
The maximum vertical length from the boiler, including the kit terminal, is 7 metres. Each 90°
elbow, or two 45° elbows, will reduce the available length by 1 metre. One horizontal metre is the
equivalent of 2 metres.
Vertical outlet kit
80/125
Code C GAS000231
Black tile
80/125
C ode
CGAS000074
45º elbow
80/125
Code
CGAS000183
90º elbow
80/125
Code
CGAS000182
1 m coaxial duct
80/125
Code CGAS000184
Black tile
80/125
Code
CGAS000075
Examples of installation:
L
7 mts.