BOILER SECURITY SYSTEMS
The boiler has two types of safety blockings:
17.1
Boiler temperature safety locking
This locking is activated when the temperature in the boiler increases over 110 ºC. To release it,
press the safety thermostat button after first removing its cap.
17.2
Low pressure locking
This locking occurs when the installation pressure drops below 0.6 bar, preventing the boiler from
functioning when there is not water in the installation, due to either leakage or maintenance
operations. To release boiler functioning, fill the installation again until a pressure of 1 - 1.5 bar is
shown on the manometer
(3)
.
NOTE: If any of the locks was repetitive, call your nearest official Technical Assistance Service.