17
If there is a buffer tank and a DHW tank (see
Example of installation with buffer
tank and DHW tank
), the selected parameter is 02. In order to work with a DHW
tank, a domestic hot water temperature sensor (see
Electrical Diagram
) and a 3-
way valve must be connected in the "
" connector (see
Electrical Connection
).
IMPORTANT: Hydraulic installation types 01 and 03 are not operational in
Lignum NG boilers.
Boiler adjustment mode. There are 3 options:
-
Classic Adjustment. 01
-
PID adjustment based on the boiler temperature adjustment. 02
-
PID adjustment based on the fume temperature adjustment. 03.
Recommended parameter: 02 (PID adjustment based on boiler temperature)
Service menu symbol.
To select the parameters, press "F". Use the
“
+
”
and
“
-
“
buttons to increase or reduce the value of the
selected parameter (the value will be flashing). Check that the value shown on the boiler temperature
set-point indicator is the one desired.
IMPORTANT: If the fume temperature is selected as an adjustment parameter, it must be taken into
account that the real value is 10 times greater than that selected. For example 20ºC
means 200ºC.