25
BIOCLASS iC DX
6
OPERATING WITH BIO HYDRAULIC KITS (OPTIONAL)
All the models within
Bioclass iC DX
range of boilers may be installed together with a
BIO Hydraulic
Kit
to regulate more than one heating circuit. Up to 3 heating circuits can be managed depending on the
BIO Hydraulic Kit chosen. For a detailed description of the functioning of the Kit, read the manual supplied
within the Kit. Nevertheless the following guidelines are given:
Direct circuit functioning
When the direct circuit pump is configured for a heating circuit (
P.23 = 0
), said circuit will work with the
selected boiler temperature setpoint and the temperature of the room thermostat or sensor
TA1
or a
LAGO FB OT+ remote control, both connected to the boiler terminal strips (see "Connection Diagrams").
When the boiler has an outside temperature, either read by the sensor connected to the
BIO Hydraulic
Kit
, or taken from the Internet (by registering the boiler in the
iConnect
application), you can select the
operation of the direct circuit according to the outside weather conditions using parameter
P.10
of the
boiler's "Technical Menu", in such a way that the boiler temperature setpoint will depend on the outside
temperature and the K Curve selected in parameter
P.45
.
Mixing circuit nº 1 functioning
The mixed heating circuit No. 1 will work with the setpoint of the flow temperature of the mixed circuit
No. 1 selected in the "User Menu" and the temperature of the room thermostat
TaM1
or LAGO FB OT +
remote control, connected in the
BIO hydraulic kit
(see " Connection Diagrams "of the Hydraulic Kit
manual)
. (15) When the boiler has an outside temperature, either read by means of the probe connected
to the
BIO Hydraulic Kit
, or obtained through the Internet (by registering the boiler in the
iConnect
application), the operation of the heating circuit no. 1 according to the outside weather conditions, using
parameter
P.10
of the "Technical Menu" of the boiler, in such a way that the flow temperature setpoint
of circuit no. 1 will depend on the outside temperature and the Curve K selected in parameter
P.11
.
Mixing circuit nº 2 functioning
The mixed heating circuit No. 2 will work with the setpoint of the flow temperature of the mixed circuit
No. 2 selected in the "User Menu" and the temperature of the room thermostat
TaM1
or LAGO FB OT +
remote control, connected in the
BIO hydraulic kit
(see " Connection Diagrams "of the Hydraulic Kit
manual)
. When the boiler has an outside temperature, either read by means of the probe connected to
the
BIO Hydraulic Kit
, or obtained through the Internet (by registering the boiler in the
iConnect
application), the operation of the heating circuit no. 2 according to the outside weather conditions, using
parameter
P.10
of the "Technical Menu" of the boiler, in such a way that the flow temperature setpoint
of circuit no. 2 will depend on the outside temperature and the Curve K selected in parameter
P.12
.