45
BIOCLASS iC DX
13
TECHNICAL MENU
"
Technical Menu
" consists of a number of technical operating parameters that only have to be modified
by a person with sufficient technical knowledge of the meaning of each parameter. Any inappropriate
setting of a parameter of
“Technical Menu”
can cause a serious malfunctioning of the boiler and could
cause damages to people, animals or things.
To access the
“Technical Menu"
press MENU and RESET tactile buttons together for 5 seconds. Access
code ("cod") request will be displayed (see
"Entry and set the access code")
. After entering the correct
code, the first parameter of
"Technical menu"
will be displayed. Browse through the menu (
P.01
, ...,
P.53
) by pressing the symbols "
+
" or "
-
" of heating
(18)
. When the desired parameter is displayed, press
to access and set it by pressing the symbols "
+
" or "
-
" of DHW
(19)
. When the parameter has been
set, press
again, the value will be saved and the display will return to
“Technical menu”
. Press RESET
any time to go back without recording any value. The following table lists these parameters and they are
described in detail in the following sections of the manual:
Nº
Parameter
Display
Cod
Access code
(by default 1234)
P.01
Boiler model
P.02
Minimum boiler heat output (%)
P.03
Maximum boiler heat output (%)
P.04
General fan speed factor (%)
(Visible only with C.01 = 0 or C.01 = 1)
P.05
Fuel for ignition (g)
P.06
Fuel consumption (kg/h)