23
6.3
Boiler temperature set point selection
Boiler temperature set point selection is made by the tactile selector shown in the picture. Press “
+
”
and “
-
“ buttons to increase or decrease the set point desired. Few seconds after the desired set
point temperature is adjusted the display returns to main position. The range of values for boiler
temperature set point is OFF, 65 - 80 ºC.
It is also possible to set boiler temperature set point browsing through the
“User Menu”
by pressing
MENU
button. When parameter
“Boiler set point temperature
”
is displayed, the boiler temperature
set point is set by pressing “
+
” and “
-
“ buttons.
When the
"OTC operating mode"
is activated by means of
P.10
parameter of
“Technical Menu”
and
the K-factor is set for the heating circuit of the boiler (or direct heating circuit of
BIO Hydraulic Kit
),
the boiler temperature set point is calculated depending on the K-factor selected. The boiler
temperature set point parameter only allows to set between activating ("
ON
") or deactivating ("
OFF
")
the heating service.
It is possible to disable the heating service of the boiler (
Summer
mode) by setting to "
OFF
" the
boiler temperature set point by pressing “
-
“symbol for heating
(18)
.
6.4
DHW temperature set point selection (with DHW tank installed only)
DHW temperature set point selection is made by the tactile selector shown in the picture. Press “
+
”
and “
-
“ buttons to increase or decrease the set point desired. Few seconds after the desired set
point temperature is adjusted the display returns to main position. The range of values for DHW
temperature set point is OFF, 15 - 65 ºC.
It is also possible to set the DHW temperature set point browsing through the
“User Menu”
by
pressing
MENU
button. When parameter
“DHW temperature set point
”
is displayed, the DHW
temperature set point is set by pressing “
+
” and “
-
“ buttons.
It is possible to disable the DHW service by setting to "
OFF
" the DHW temperature set point by
pressing “
-
“ for DHW
(19)
.