High Flo Inlet Plenum
The high flo inlet plenum is used in applications with
higher flow rates.
The high flo inlet plenum is supplied with standard
service access panels on the front, back and top of the
plenum
The top access panel is available with and without an
explosion vent.
Inlet Plenum
The inlet plenum is standard on Downflo Evolution
collectors unless another inlet plenum option has been
selected.
The inlet plenum directs the dirty air stream to the back
of the dirty-air plenum over the venturi section.
1. Remove the collector's shipping cover plate.
Remove excess sealant from opening.
2. Apply 1/4-in sealant around the opening toward the
inside edge of the bolt pattern.
3. Align the holes on the inlet collar with the holes in
the collector and secure using 3/8-16 x 1-in bolts and
flat washers supplied.
High Flo Inlet Plenum
Inlet Plenum