Downflo II, Models DFT 2-4 and DFT 3-6
23
1. Place a 1/4-in diameter, rope-type sealant
between the hopper flange and the adapter as
shown.
2. Attach the adapter to the hopper flange using
3/8-16 bolts, washers, and hex nuts.
3. Attach the drum cover to the 55-gallon drum.
4. Use latches to secure the cover to the drum, if
equipped.
5. Connect the flexible hose between the drum
cover and the adapter. Secure with hose clamps.
55-Gallon Drum Pack without Slide Gate
hopper flange
drum cover
optional latch
customer-supplied
55-gallon drum
hose clamp
flexible hose
1/4-in diameter
rope-type sealant
3/8-16 bolt
3/8-in flat washer
3/8-in lock washer
3/8-16 hex nut
adapter