background image

3

Donaldson Company, Inc.

Inspection on Arrival

1.  Inspect collector upon delivery.
2.  Report any damage to the delivery carrier.
3.  Request a written inspection report from the Claims 

Inspector to substantiate any damage claim.

4.  File claims with the delivery carrier.
5.  Compare collector received with description of 

product ordered.

6.  Report incomplete shipments to the delivery carrier 

and your Donaldson Torit representative.

7.  Remove crates and shipping straps. Remove loose 

components and accessory packages before lifting 

collector from truck. 

8.  Check for hardware that may have loosened during 

shipping.

9.  Use caution removing temporary covers.

Installation Codes and Procedures

Codes may regulate recirculating 

filtered air in your facility. 

Consult with the appropriate authorities 

having jurisdiction to ensure compliance 

with all national and local codes regarding 

recirculating filtered air.

Safe and efficient operation of the collector depends on 

proper installation.  
Authorities with jurisdiction should be consulted 

before installing to verify local codes and installation 

procedures. In the absence of such codes, install 

collector according to the National Electric Code, 

NFPA No. 70-latest edition and NFPA 91 (NFPA 654 if 

combustible dust is present).
A qualified installation and service agent must complete 

installation and service of this equipment.
All shipping materials, including shipping covers, must 

be removed from the collector prior to or during collector 

installation.

Failure to remove shipping 

materials from the collector will 

compromise collector performance.

Inspect collector to ensure all hardware is properly 

installed and tight prior to operating collector.

Installation

Use proper equipment and adopt 

all safety precautions needed for 

servicing equipment.  
Electrical service or maintenance work must 

be performed by a qualified electrician and 

comply with all applicable national and local 

codes.
Turn power off and lock out electrical 

power sources before performing service or 

maintenance work.
Do not install in classified hazardous 

atmospheres without an enclosure rated for 

the application.

Site selection must account for 

wind, seismic zone, and other 

load conditions  when selecting the location for  

collectors.      
Codes may regulate acceptable locations for 

installing dust collectors.  Consult with the 

appropriate authorities having jurisdiction to 

ensure compliance with all national and local 

codes regarding mist collector installation.
Collectors must be anchored in a manner 

consistent with local code requirements. 

Anchors must be sufficient to support dead, 

live, seismic, and other anticipated loads.  
Consult a qualified engineer for final selection 

of anchorage.

The collector is suitable for indoor installation. Reference 

the Rating and Specification Information. 

Foundations or Support Framing

Prepare the ceiling or machine mounting structure in the 

selected location. Mounting structure must comply with 

local code requirements and may require engineering. 
Foundation and support framing must be capable of 

supporting dead, live, wind, seismic and other applicable 

loads. Consult a qualified engineer for final selection of 

foundation or support framing.

Summary of Contents for E-100

Page 1: ...th the collector when set up and start up are complete Donaldson Company reserves the right to change design and specifications without prior notice Illustrations are for reference only as actual product may vary Centrifugal Mist Collector E 100 E 200 E 300 E 500 EA 700 EA 900 and EA 905 Installation and Operation Manual Installation Operation and Service Information IOM 1B0510107 ENG Revision 3 E...

Page 2: ...bilities are met As a manufacturer and supplier of Industrial Filtration Products Donaldson can assist process owners operators in the selection of filtration technologies However process owners operators retain all responsibility for the suitability of fire and explosion hazard mitigation suppression and isolation strategies Donaldson assumes no responsibility or liability for the suitability of ...

Page 3: ...rdous situation which if not avoided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury that may result in damage to equipment Centrifugal Mist Collector E 100 to EA 905 i Data Sheet Contents Description 1 Pu...

Page 4: ...ers are used to remove chips or solid particles before they enter the rotating drum and impingers remove heavy sprays of raw fluids Optional HEPA afterfilters available in standard and high capacity sizes remove smoke generated in a machine process while carbon afterfilters remove gas vapor and odors Centrifugal Mist Collectors are intended for separation of various liquid droplets and particulate...

Page 5: ...w to large droplet size These filters are housed in a spinning perforated drum with internal radial fan blades to promote air movement The droplets are spun and thrown from the perforated drum to the inner wall of the collector housing by centrifugal force High velocity air drives the liquid or oil along the housing walls through a circumferential slot and into a collection chamber where the liqui...

Page 6: ...e to remove shipping materials from the collector will compromise collector performance Inspect collector to ensure all hardware is properly installed and tight prior to operating collector Installation Use proper equipment and adopt all safety precautions needed for servicing equipment Electrical service or maintenance work must be performed by a qualified electrician and comply with all applicab...

Page 7: ... equipment is not designed to support site installed ducts interconnecting piping or electrical services All ducts piping or electrical services must be adequately supported to prevent severe personal injury and or property damage When hazardous conditions or materials are present consult with local authorities for the proper location of the collector Mist collection equipment may reach peak sound...

Page 8: ...nt deposits of oil from settling at low points and blocking the air passage 3 If rigid duct is used connect an 18 in length of flexible hose to the unit s inlet cover for easy cover removal Electrical Wiring Electrical installation service or maintenance work must be performed by a qualified electrician and comply with all applicable national and local codes Turn power off and lock out electrical ...

Page 9: ...that connects to the reservoir eliminating the need to empty containers A separate container can be attached to the drain if desired Secondary Drain The secondary drain fitting is a 1 4 in NPT 900 EL fitting and connects the same way the primary drain connects Do not submerge ends of hose Do not connect the secondary drain hose to the primary drain hose in cover trap drain hose without in cover tr...

Page 10: ...ram Electrical Connection Electrical installation must be performed by a qualified electrician and comply with all applicable national and local codes Lock out electrical power sources before performing service or maintenance work Do not install in classified hazardous atmospheres without an enclosure rated for the application Wire unit according to the wiring diagram located on the motor conduit ...

Page 11: ...ate To reverse rotation three phase power supply Switch any two leads on the motor junction box Do not look into fan outlet to determine rotation View the fan rotation through the back of the motor Check that the exhaust plenum is free of tools or debris before checking blower fan rotation Stand clear of exhaust to avoid personal injury Do not interchange a power lead with the ground wire Severe p...

Page 12: ...disposable liner 3 Starting at the mark made in Step 1 slide the replacement liner under each blade until the ends come together Do not trim the filter if it seems too long Work the excess filter liner around the drum evenly 4 Replace the cover and clamping ring turn power ON and allow unit to reach full speed 5 Turn unit OFF and allow drum to stop Remove the inlet cover and inspect liner It shoul...

Page 13: ...st Collector E 100 to EA 905 10 Optional Equipment PrefilterTrap in cover trap retainer filter o ring v ring tee 1 2 in flexible tube wing nut lock washer flat washer hex nut Prefilter Trap In Cover Trap In CoverTrap ...

Page 14: ...11 Donaldson Company Inc 1 2 x 1 2 x 1 2 in barbed nylon tee 1 2 in flexible tube V ring in cover housing impinger O ring hex nut lock washer In Cover Impinger In Cover Impinger ...

Page 15: ...Centrifugal Mist Collector E 100 to EA 905 12 HEPA Filter cover HEPA filter HEPA filter housing 10 x 1 in self tapping screw silicone sealant HEPA Filter ...

Page 16: ...tly Check wiring in junction box for tightness and contact Defective motor Replace motor Collector runs slow Incorrect voltage Check power supply circuit for proper voltage Junction box not wired correctly Check that the junction box is wired according to the wiring diagram Single phase disconnected Check that the junction box is wired according to the wiring diagram Obstruction between drum and h...

Page 17: ...Centrifugal Mist Collector E 100 to EA 905 14 Service Notes Date Service Performed Notes ...

Page 18: ...15 Donaldson Company Inc Service Notes Date Service Performed Notes ...

Page 19: ......

Page 20: ...e to corrosion abrasion normal wear and tear product modification or product misapplication Donaldson also makes no warranty whatsoever as to any goods manufactured or supplied by others including electric motors fans and control components After Donaldson has been given adequate opportunity to remedy any defects in material or workmanship Donaldson retains the sole option to accept return of the ...

Reviews: