Bin Vent, Models TBV-2, TBV-4, and TBV-6
7
Inspection on Arrival
1. Inspect unit on delivery.
2. Report any damage to the delivery carrier.
3. Request a written inspection report from the
Claims Inspector to substantiate claim.
4. File claims with the delivery carrier.
5. Compare unit received with description of
product ordered.
6. Report incomplete shipments to the delivery
carrier and your Donaldson representative.
7. Remove crates and shipping straps. Remove
loose components and accessory packages before
lifting unit from truck.
Installation Codes and Procedures
OSHA may have requirements
regarding recirculating filtered
air in your facility. Consult with the
appropriate local authorities to ensure
compliance with all codes regarding
recirculating filtered air.
Safe and efficient operation of the unit depends on
proper installation.
Authorities with jurisdiction should be consulted
before installing to verify local codes and installation
procedures. In the absence of such codes, install unit
according to the National Electric Code, NFPA No.
70-latest edition.
A qualified installation and service agent must
complete installation and service of this equipment.
All shipping materials, including shipping covers,
must be removed from the unit prior to, or during
unit installation.
Failure to remove shipping
materials from the unit will
compromise unit performance.
NOTICE
Installation
Site Selection
The unit can be located in the top of storage silos
and bins, or integrated into hoods for material
handling equipment such as belt conveyors and
bucket elevators or process equipment such as
blenders and crushers.
Wind, seismic zone, and other live-load conditions
must be considered when designing the mounting
flange and hood supports for the collector. Reference
the Rating and Specification Information section.
Provide appropriate clearance from heat sources and
interference with utilities.
Unit Location
When hazardous conditions or materials are present,
consult with local authorities for the proper location
of the unit.
Mounting flanges and hood supports must be
capable of supporting the entire weight of the unit
plus the weight of the collected material, piping, and
ductwork. Reference the Rating and Specification
Information.
Locate the unit to ensure the shortest and straightest
inlet- and outlet-duct length, easy access to electrical
and compressed-air connections, and routine
maintenance.